Laserfiche WebLink
further acid or any other chemical should be added to the water. <br /> The vials will be placed on ice in a cooler and kept on ice until <br />' delivered to the lab or turned over to their courier within 48 <br /> hours of the sampling time. <br /> Purged water will be placed in a sealed drum and left at the <br /> I <br /> site. The drums will be labeled for the source of the water. <br /> After the chemical analyses are completed the contamination in <br /> each drums will be assessed. if the chemical analyses of the <br /> water in a drum shows the water to be free of contamination then <br /> this water will be disposed of as clean water. Contaminated water <br /> will be removed from the site by a licenced waste hauler. <br /> Water samples will be taken from the water at or near the surface <br /> of the water table, unless otherwise indicated. The containers <br /> will be filled so that zero headspace is present in the sealed <br /> vial before placing in the cooler. Trip blanks will accompany <br /> all sample containers. A Chain of Custody will be filled out by <br /> the sampler. The tests run will be as follows: <br /> ITest Detection <br /> Limits <br /> DHS TPH Method (gasoline) 500 ug/L <br /> EPA 602 for <br /> Benzene 0 . 5 ug/L <br /> Toluene 0.5 ug/L <br /> Ethyl Benzene 0.5 ug/L <br /> Xylenes 0 . 5 ug/L <br /> All laboratory results, well measurements and the Chain of <br /> Custody must be sent to our office for evaluation and the <br /> preparation of a report. <br /> I <br /> I <br /> I <br /> I <br /> I <br /> 1 <br /> I <br />