My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL 1987
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WILSON
>
130
>
2300 - Underground Storage Tank Program
>
PR0231861
>
INSTALL 1987
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/5/2019 4:51:45 PM
Creation date
3/5/2019 2:29:16 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
1987
RECORD_ID
PR0231861
PE
2361
FACILITY_ID
FA0003601
FACILITY_NAME
ARCO STATION #826951*
STREET_NUMBER
130
Direction
S
STREET_NAME
WILSON
STREET_TYPE
WAY
City
STOCKTON
Zip
95205-5561
APN
15502064
CURRENT_STATUS
01
SITE_LOCATION
130 S WILSON WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
56
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
13 <br /> � S P E C I FI C A T I O N S <br /> r <br /> 8. Submittals: <br /> a. Shop Drawings:Contractors shall submit copies of <br /> shop drawings for each tank. Drawings shall include all <br /> critical dimensions and show locations of all fittings and <br /> accessories, i.e., manways, ladders, hold-down straps, <br /> heating coils, etc. Materials of construction shall be in <br /> accordance with Section 1.02 of this specification. <br /> b.Catalog Data:Contractor shall submit copies of <br /> Fiberglas" Tanks for manufacturer's literature. <br /> c.Certification Plate: U.L. labels for petroleum products shall <br /> Fuel Storage be affixed to each tank. <br /> d. Installation Instructions:Contractors shall submit <br /> copies of manufacturer's latest installation instructions. <br /> Specification e.Calibration Charts:Contractors shall submit <br /> — <br /> copies copies of manufacturer's latest calibration charts. <br /> Short Form: <br /> The contractor shall provide Fiberglas underground storage tanks 1.03 Warranty—Standard Underground Petroleum Storage Tank <br /> U.L-labeled for petroleum products in sizes and with fittings as shown A.Tank manufacturer shall furnish a warranty stating as follows: <br /> on the drawings.The tanks shall be manufactured by Owens-Corning We warrant that our underground tanks, if installed <br /> f Fiberglas. underground with proper backfill and otherwise installed in <br /> j Tanks shall be tested and installed with pea gravel or approved accordance with our instructions: <br /> alternate backfill material according to the current installation 1.Will meet our published specifications and will be free from <br /> instructions(Owens-Corning Fiberglas publication 3-PE-6304) material defects in materials and workmanship for a period <br />.1 provided with the tank. of one(1)year following date of original delivery by us; <br /> Long Form: Section 13177.1 2.Will not fail for a period of thirty(30)years from date <br /> (� GUIDE SPECIFICATION of original purchase due to external corrosion, and; <br /> 3.Will not fail for a period of thirty(30)years from date of <br /> OWENS-CORNING FIBERGLAS <br /> original purchase due to internal corrosion, provided the <br /> REINFORCED POLYESTER tank is used solely for gasoline,gasohol(90% gasoline and <br /> UNDERGROUND STORAGE TANKS 10% ethanol mixture), 90.5% gasoline and 9.5% Oxincl-50* <br /> (4.75% methanol and 4.75% GTBA mixture),jet fuel,av gas, <br /> ti <br /> kerosene,diesel fuel or potable water at ambient <br /> underground temperatures; or used for fuel oil at <br /> Part I General temperatures not to exceed 150° F. <br /> 1.01 Related Work Specified In Other Sections 4. Will not leak for a period of thirty(30)years from date of <br /> A.Cast-in-Place Concrete: Section 03300 original purchase due to structural failure which shall be <br /> defined as breaking or collapse provided the installation is <br /> B.Anchor Bolts: Section 05501 <br /> I in the United States and is performed and validated by a <br /> C. Plastic Pipe:Section 15064 contractor trained by Owens-Corning and the tank is used <br /> D. Liquid Level Gauges:Section 15174 as stated above. <br /> E.Other Related Work—such as Excavation and Boiler Equipment Our liability under this warranty shall be limited to,at our option, <br /> (i)repair of the defective tank,(ii)delivery of a replacement tank to the <br /> point of original delivery,or(iii)refund of the original purchase price, <br /> 1.02 Quality Assurance and we shall not be liable for any labor,other installation costs, <br />_ indirect or consequential damages or other damages in connection <br /> A. Acceptable Manufacturers:Owens-Corning Fiberglas Corp. with such tanks. THE FOREGOING CONSTITUTES OUR <br />'• Toledo, Ohio <br /> EXCLUSIVE OBLIGATION AND WE MAKE NO EXPRESS OR <br /> B.Governing Standards: IMPLIED WARRANTIES. OR ANY WARRANTY OF MERCHAN- <br /> 1.ASTM Specification D4021-81.Glass Fiber Reinforced TABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE <br /> Polyester Underground Petroleum Storage Tanks. WHATSOEVER, EXCEPT AS STAIED ABOVE. <br />_ 2. U.L. 1316. Underwriters Laboratories, Inc.,Glass Fiber <br /> Reinforced Plastic Underground Storage Tanks for <br /> Petroleum Products. Part II Products <br /> 3. National Fire Protection Assoc.(NFPA 30)Flammable and 2.01 Fiberglas Underground Storage Tanks. <br /> Combustible Liquids Code and(NFPA 31)Standards for A. Loading Conditions—Tank shall meet the following design criteria: <br /> Installation of Oil Burning Equipment. 1. External hydrostatic pressure. Buried in ground with 7' of <br /> 4. Factory Mutual File OFGA8.AF. overburden over the top of the tank.The hole fully flooded <br /> (� 5. National Sanitation Foundation Testing Laboratory,January 1984, and a safety factor of 2:1 against general buckling. <br /> listing of Plastic Piping System Components And Related 2. Surface loads:When installed according to manufacturer's <br /> Materials,Standard 14. installation instructions tanks will withstand surface H-20 axle <br /> ? 6. Military Specification MIL-T-52777A,dated July 6, 1978,Tanks, loads(32,000 lbs./axle). <br /> Storage, Underground,Glass Fiber Reinforced Plastic. 3. Internal load:Tank shall withstand pressure test of 5 psi on tanks <br /> 7. General Services Administration, Public Building Service of 4' through 10'diameters;3 psi on 12'diameter tanks.A <br /> Guide Specification, PBS: 1568. 5 to 1 safety tactor. <br /> TM Arco Chemical Co. <br />