Laserfiche WebLink
14 <br /> • <br /> 4.Tanks shall be designed to support accessory equipment such <br /> as heating coils, ladders,drop tubes, etc.when installed <br /> according to manufacturer's recommendations and <br /> limitations. <br /> B.Product Storage Requirements: <br /> 1:All tanks must be vented.Tanks are designed for operation <br /> at atmospheric pressure only, except for use with vapor <br /> recovery systems providing the pressure or vacuum does <br /> not exceed 1 psi. <br /> 2.Tanks shall be capable of storing liquids with specific gravity <br /> up to 1.1. <br /> 3. Maximum temperature.Tanks shall be listed by a nationally <br /> recognized laboratory and capable of storing gasoline, gasohol <br /> (90%gasoline and 10% ethanol mixture),90.5%gasoline and <br /> and 9.5% Oxinol-50' (4.75% methanol and 4.75% GTBA mixture), E. Heating Coils/Hotwells <br /> av gas,jet fuel, diesel fuel, motor oil or oil at temperatures not to 1. Heating Coils-shall be standard item as manufactured and/or <br /> exceed 150°F at the tank interior surface. supplied by the tank manufacturer including 22" manway. <br /> 4.Tanks shall be chemically inert to petroleum products. 2. Location-refer to drawings for location. <br /> C. Dimensional Requirements(refer to Owens-Corning literature F. Fittings-Threaded-NPT <br /> on gallonage.) 1.All threaded fittings on U.L.-labeled tanks for storage of petroleum <br /> 1. Nominal capacity of the tank shall be gallons. products shall be of a material of.construction consistent with the <br /> 2. Nominal outside diameter of the tanks shall be feet. requirements of the U.L.-label.All fittings to be supplied with <br /> 3.Approximate overall length of the tanks shall be feet. threaded plugs. <br /> 2.All standard threaded fittings are 4" in diameter and shall be half <br /> couplings. Reducers are to be used for smaller sizes where <br /> 2.02 Accessories specified and provided by contractor. <br /> 3 <br /> A.Anchor Straps-Provide glass fiber-reinforced plastic anchor .Thread Standards-All threaded fittings shall have machine <br /> tolerances in accordance with the ANSI standard for each <br /> straps for each tank shown. Number and location of straps <br /> shall be as specified by manufacturer. Each strap shall be fitting size. <br /> capable of withstanding the bouyancy load for tank diameter 4. Strength-NPT fittings will withstand a minimum of 150 foot- <br /> as shown. pounds of torque and 1,000 foot-pounds of bending, both with <br /> 4'0- 4,200 lbs. 8'0-25,000 lbs. 12'�-26,000 lbs. 2:1 factor of safety. <br /> 6'0-18,OOO lbs. 10'x-32,000 lbs 5. Sizes Standard Other Sizes <br /> Straps shall be standard as supplied by the tank manufacturer. Inlet 4" --. <br /> Outlet --__- <br /> 4" <br /> B.Certification Plate-Underwriters' Laboratory label Vent 4" <br /> shall be permanently affixed to each tank. Gauge 4" <br /> Fill' 4- <br /> C Flanged Manways <br /> 1.The standard manways to be 22" I.D. the 30" and 36" I.D. 6. Location-refer to drawings for location. <br /> manways to be installed in 6',8', 10' and 12'diameter tanks 7. Suction Line-Shall be installed on site by the contractor. <br /> only. Diameter of pipe and grade and schedule as called out in other <br /> i <br /> 2.All manways will be furnished complete with U.L.approved sections. <br /> gaskets, bolts and covers. 8. Return Line-Shall be installed on the site by the contractor. <br /> 3. Location-refer to drawings for location. Diameter of pipe and grade and schedule as called out in other <br /> sections. <br /> 4 4. Manway risers 48" in diameter,and 42" high will <br /> be supplied to provide access to the manway lid.A 9. All rigid piping shall terminated a minimum of 4" from the <br /> eight <br /> bottoms of four, six,eight and ten foot diameter tanks, and a <br /> 24" x 24" galvanized street box with a cover must be minimum of 6" from the bottoms of twelve foot diameter tanks. <br /> provided by contractor for at grade installation. <br /> G. Ladders-Shall be standard carbon steel supplied by the tank <br /> 5. Fiber glass manway extension tubes 24" long will be • <br /> manufacturer. Refer to drawings for location. <br /> provided for the manways as outlined in section 3 above. <br /> D. Fill Tubes H. Lifting Lugs-Provide lifting lug(s)on all tanks. Lugs shall be <br /> capable of withstanding weight of tank with a safety factor of <br /> 1.Tubes shall be fiber glass-reinforced plastic. 3 to 1. <br /> 2.Tubes shall be factory installed,4" diameter,and shall <br /> include a 6" steel fitting with a double tapped reducer <br /> bushing to 4" diameter. Part III Execution <br /> 3.Tubes shall be standard items as manufactured and installed 3.01,3.02 Installation and testing <br /> by the tank manufacturer. Tanks shall be tested and installed according to the current <br /> 4. FRP fill tubes supplied by Owens-Corning.Other fill tubes of installation instructions provided with the tank(refer to Owens-Corning <br />=_ appropriate design can be supplied by contractor. Fiberglas publication 3-PE-6304 and include as part of your <br /> 5. Location-refer to drawings for location. specification). <br /> 'TM Arco Chemical Co. <br />