Laserfiche WebLink
FIED PROGRAM CONSOLIDATED FORM TANK: TA0186101 <br /> PR#: PR0231861 <br /> UNDERGROUND STORAGE TANKS - TANK PAGE 1 FAC#: FA0003601 <br /> Af(314a77 (two pages per tank) <br /> TYPE OF ACTION Page 2 of 7 <br /> (Check onlr item only) ❑ INEW SITE PERMIT 4.AMENDED PERMIT ❑ 5Ct1ANGE OF INFORMATION ❑ 6 TEMPORARY SITE CLOSURE <br /> ❑ 7 PERMANENTLY CLOSED ON SITE <br /> 3 RENEWAL PERMIT (Spccifj•reasat•.for local use only) (SpxlCy reason-for local use only) <br /> ❑ ❑8 TANK REMOVED 430 <br /> BUSINESS NAME(Same as FACILITY NAME or DBA-Doing Business As) FACILITY ID: PR#: I <br /> ARCO STATION#5469* 3 FA0003601 PR0231861 <br /> LOCATION WITHIN SITE(Optional) 130 S WILSON WAY,STOCKTON 431 <br /> PHONE <br /> I.TANK DESCRIPTION(A scaled plot plan with the location of the UST system including buildings and landmarks shall be submitted to the local agency.) <br /> TANK ID# Tank#: 1 432 TANK MANUFACTURER 433 COMPARTMENTALIZED TANK ❑Yes ❑No 434 <br /> TA0186101 OWENS CORNING If"Yes",complete one page for each compaement. <br /> DATE INSTALLED(YEAR/MO) 435 TANK CAPACITY IN GALLONS 436 NUMBER OF COMPARTMENTS 337 <br /> 1/1/1988 12:00:OOAM 12,000 <br /> ADDITIONAL DESCRIPTION(For local use only 338 <br /> CHNG PE FR 2380 TO 2360 PER LGB 3/13/00 LB <br /> IL TANK CONTENTS <br /> TANK USE 439 PETROLEUM TYPE 430 <br /> ® L MOTOR VEHICLE FUEL ® 1 a.REGULAR UNLEADED ❑ 2.LEADED ❑ 5.JET FUEL <br /> (lfmarked complete Petroleum Type) ❑ I b.PREMIUM UNLEADED ❑ 3.DIESEL ❑6.AVIATION FUEL <br /> ❑ 2.NON-FUEL PETROLEUM ❑ I a MIDGRADE UNLEADED ❑4.GASOHOL ❑99.OTHER <br /> ❑ 3.CHEMICAL PRODUCT <br /> COMMON NAME(frotm Hazardous Materials Inventory page) 441 CAS#(from Hazardous Materials Inventory page) 332 <br /> ❑4.HAZARDOUS WASTE <br /> (Includes Used Oil) <br /> ❑ 95.UNKNOWN <br /> III.TANK CONSTRUCTION <br /> TYPE OF TANK ❑ I.SINGLE WALL ❑ 3.SINGLE WALL WITH ❑ 5.SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443 <br /> (Chock one item only) EXTERIOR MEMBRANE LINER E195.UNKNOWN <br /> ®2.DOUBLE WALL ❑4.SINGLE WALL IN VAULT ❑99.OTHER <br /> TANK MATERIAL-primary tank ❑ I.BARE STEEL ® FIBERGLASS/PLASTIC ❑ 5.CONCRETE ❑95.UNKNOWN 333 <br /> (Check one item only) ❑ 2.STAINLESS STEEL ❑ STEEL CLAD W/FIBERGLASS ❑ 8.FRP COMPTIBLE W/1008/6 METHANOL <br /> REINFORCED PLASTIC(FRP) ❑99.OTHER <br /> TANK MATERIAL-secondary tank ❑ I.BARE STEEL ❑ 3.FIBERGLASS/PLASTIC ❑ 5.CONCRETE ❑95.UNKNOWN 445 <br /> (Check one item only) E]2.STAINLESS STEEL ❑ 4.STEEL CLAD W/FIBERGLASS ❑ 8.FRP COMPTIBLE W/100%METHANOL <br /> REINFORCED PLASTIC(FRP) ❑ 10.COATED STEEL ❑99.OTHER <br /> ❑ 5.CONCRETE <br /> TANK INTERIOR LINING ❑ 1.RUBBER LINED E]3.EPDXY LINING E]5.GLASS LINING ❑95.UNKNOWN 446 DATE INSTALLED 447 <br /> OR COATING <br /> (Check one item only) 2 ALKYD LINING E]4 PHENOLIC LINING ®6 UNLINED E] 99.OTHER <br /> (For local use only) <br /> OTHER CORROSION ❑ I MANUFACTURING CATHODIC ® 3 FIBERGLASS REINFORCED PLASTIC ❑95 UNKNOWN 448 DATE INSTALLED <br /> PROTECTION IF APPLICABLE PROTECTION <br /> (Check one item only) ❑ 4 IMPRESSED CURRENT ❑ 99 OTHER <br /> ❑ 2 SACRIFICIAL ANODE (For beat use only) <br /> 1 SPILL AND OVERFILL YEAR INSTALLE450 TYPE(local use only) 451 OVERFILL PROTECTION EQUIPMENT:YEAR INSTALLED 452 <br /> (Cheek all that apply) ® I SPILL CONTAINMENT l rigs s.g Z Db S / ® I ALARM ❑ 3 FILL TUBE SHUT OFF VAL' <br /> ❑ 2 DROP TUBE fa 2 BALL ❑4 EXEMPT <br /> 3 STRIKER PLATE FLOAT <br /> IV.TANK LEAK DETECTION(A description of the monitoring program shall be submitted to the local agency.) <br /> IF SINGLE WALL TANK(Check all that apply) 453 IF DOUBLE WALL TANK OR TANK WITH BLADDER 354 <br /> ❑ 1 VISUAL(EXPOSED PORTION ONLY) ❑ 5 MANUAL TANK GAUGING(MTG) (Check one teem only) <br /> ❑2 AUTOMATIC TANK GAUGING(ATG) ❑6 VADOSE ZONE ❑ I VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑3 CONTINUOUS ATG ❑ 7 GROUNDWATER ®2 CONTINUOUS INTERSTITIAL MONITORING <br /> ❑ 4 STATISTICAL INVENTORY RECONCILIATION ❑ 8 TANK TESTING ❑3 MANUAL MONITORING <br /> (SIR)BIENNIAL TANK TESTING ❑99 OTHER <br /> V.TANK CLOSURE INFORMATION/PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) 455 1 ESTIMATED QUANTITY OF SUBSTANCE REMAINING 456 TANK FILLED WITH INERT MATERIAL? 457 <br /> ❑Yes ❑ No <br /> UPCF(12/99 revised) <br />