Laserfiche WebLink
i1FIED PROGRAM CONSOLIDATED FORK O �C� TANK: TA0186101 <br /> PR#: PR0231861 <br /> AC#: FA0003601 <br /> UNDERGROUND STORAGE TANKS -TANK PAGE 2 <br /> VI.PIPING CONSTRUCTION(Check an that apply) Page;of <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SYSTEM TYPE ® 1.PRESSURE ❑2.SUCTION ❑ 3.GRAVITY 458 ❑ L PRESSURE ❑2.SUCTION ❑3.GRAVITY 459 <br /> CONSTRUCTION ❑1.SINGLE WALL ❑3.LINED TRENCH ❑99.OTHER 460El1.SINGLE WALL [j95.UNKNOWN 461 <br /> ®2.DOUBLE WALL ❑95.UNKNOWN El 2.DOUBLE WALL El 99.OTHER <br /> MANUFACTURER 461 MANUFACTURER 463 <br /> ❑ 1.BARE STEEL ❑ 6.FRP COMPATIBLE w/100°/METHANOL ❑ 1.BARE STEEL ❑ 6.FRP COMPATIBLE w/100/6 METHANOL <br /> ❑2.STAINLESS STEEL ❑ 7.GALVANIZED STEEL ❑ 2.STAINLESS STEEL ❑ 7.GALVANIZED STEEL <br /> ❑PLASTIC COMPATIBLE W/CONTENTS ❑ 95.UNKNOWN ❑ PLASTIC COMPATIBLE W/CONTENTS ❑ 95.UNKNOWN <br /> M 4.FIBERGLASS ❑ B.FLEXIBLE(HDPE) ❑ 99.OTHER ❑4.FIBERGLASS ❑ g.FLEXIBLE(HDPE) ❑ 99.OTHER <br /> ❑5.STEEL W/COATING ❑ 9.CATHODIC PROTECTION 464 ❑ 5.STEEL W/COATING ❑ 9.CATHODIC PROTECTION a,,< <br /> VII.PIPING LEAK DETECTION(Check all that apply)(A description of the monitoring program shall be submitted to the local agency.) <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SINGLE WALL PIPING 466 SINGLE WALL PIPING 467 <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check all that apply): <br /> ❑ 1.ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT OFF ❑ 1.ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT OFF <br /> FOR LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION+AUDIBLE AND FOR LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION+AUDIBLE AND <br /> VISUAL ALARMS. VISUAL ALARMS. <br /> ❑2.MONTHLY 0.2 GPH TEST ❑ 2.MONTHLY 0.2 GPH TEST ❑ 3.ANNUAL INTEGRITY TEST(0.1 GPH) <br /> ❑3.ANNUAL INTEGRITY TEST(0.I GPH) <br /> ❑4.DAILY VISUAL CHECK <br /> CONVENTIONAL SUCTION SYSTEMS CONVENTIONAL SUCTION SYSTEMS(Check all that apply) <br /> ❑5.DAILY VISUAL MONITORING OF PUMPING SYSTEM+TRIENNIEAL PIPING ❑ 5.DAILY VISUAL MONITORING OF PIPING AND PUMPING SYSTEM <br /> INTEGRITY TEST(0.1 GPH) ❑6.TRIENNIAL INTEGRITY TEST(0.1 GPH) <br /> SAFE SUCTION SYSTEMS(NO VALUES IN BELOW GROUNDPIPING): SAFE SUCTION SYSTEMS(NO VALUES IN BELOW GROUNDPIPING): <br /> ❑ 7.SELF MONITORING <br /> ❑7.SELF MONITORING <br /> GRAVITY FLOW <br /> ❑ 9.BIENNIAL INTEGRITY TEST(0.1)GPH GRAVPrY FLOW(Check all that apply): <br /> ❑ S.DAILY VISUAL MONITORING <br /> ❑ 9.BIENNIAL INTEGRITY TEST(0.1)GPH <br /> SECONDARILY CONTAINED PIPING SECONDARILY CONTAINED PIPING <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check all that apply): <br /> 10.CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL 10.CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL <br /> ALARMS AND(Check one) ALARMS AND(Check one) <br /> ❑ a.AUTO PUMP SHUT OFF WHEN A LEAK OCCURS ❑ a.AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br /> 1 b.AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM ❑ b.AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM <br /> DISCONNECTION DISCONNECTION <br /> ❑ c. NO AUTO PUMP SHUT OFF ❑ c. NO AUTO PUMP SHUT OFF <br /> 11.AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITH FLOW SHUT OFF OR ❑ 11.AUTOMATIC LEAK DETECTOR <br /> RESTRICTION <br /> ❑ 12.ANNUAL INTEGRITY TEST(0.1 GPH) ❑ 12.ANNUAL INTEGRITY TEST(0.1 GPH) <br /> SUCTION/GRAVITY SYSTEM SUCTION/GRAVITY SYSTEM <br /> ❑ 13.CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS ❑ 13.CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS <br /> EMERGENCY GENERATORS ONLY(Check all that apply) EMERGENCY GENERATORS ONLY(Check all that apply) <br /> ❑ 14.CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF• ❑ 14.CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF <br /> AUDIBLE AND VISUAL ALARMS AUDIBLE AND VISUAL ALARMS <br /> ❑ 15.AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITHOUT FLOW ❑ 15.AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITHOUT FLOW <br /> SHUT OFF OR RESTRICTION SHUT OFF OR RESTRICTION <br /> ❑ 16.ANNUAL INTEGRITY TEST(0.1 GPH) ❑ 16.ANNUAL INTEGRITY TEST(0.1 GPH) <br /> ❑ 17.DAILY VISUAL CHECK ❑ 17.DAILY VISUAL CHECK <br /> VIII.DISPENSER CONTAINMENT <br /> DISPENSER CONTAINMENT ❑ 1.FLOAT MECHANISM THAT SHUTS OFF SHEAR VALVE ❑ 4.DAILY VISUAL CHECK <br /> DATE INSTALLED 468 ❑2.CONTINUOUS DISPENSER PAN SENSOR+AUDIBLE AND VISUAL ALARMS ❑ 5.TRENCH LINER/MONITORING <br /> '3.CONTINUOUS DISPENSER PAN SENSOR WITH AUTO SHUT OFF FOR El 6.NONE <br /> DISPENSER+AUDIBLE AND VISUAL ALARMS 469 <br /> IX.OWNER/OPERATOR SIGNATURE <br /> I certify that the information provided herein is true and accuratc to the best of my knmvledgc. <br /> SIGNATURE OF OWNER/OPERATOR DATE 470 <br /> NAME OF OWNER/OPERATOR(print) TITLE OF OWNER/OPERATOR <br /> Lit.JQ T�C e 1t'�' 471 472 <br /> Pcrmit Number(For local use only) i 7; Permit Approved(For local use only) 474 Permit Expiration Date(For local use only) 475 <br /> PT0003701 EE0000817 12/31/2007 12:00:00AM <br /> UPCF(12/99 revised) <br />