My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING 2005 - 2007
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WILSON
>
130
>
2300 - Underground Storage Tank Program
>
PR0231861
>
BILLING 2005 - 2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/13/2023 4:12:00 PM
Creation date
3/7/2019 10:47:51 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
2005 - 2007
RECORD_ID
PR0231861
PE
2361
FACILITY_ID
FA0003601
FACILITY_NAME
ARCO STATION #826951*
STREET_NUMBER
130
Direction
S
STREET_NAME
WILSON
STREET_TYPE
WAY
City
STOCKTON
Zip
95205-5561
APN
15502064
CURRENT_STATUS
01
SITE_LOCATION
130 S WILSON WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FIELD PROGRAM CONSOLIDATED FORM /1/ L//'- TANK: TA0186102 <br /> lJ PR#: PR0231861 <br /> UNDERGROUND STORAGE TANKS - TANK P 1 7/1 ?'�FAc#: FAoo03601 <br /> sjz3jc (two pages per tank) <br /> TYPE OF ACTION Page 4 of 7 <br /> (Check only FitcmAC onk) ❑ INEW SITE PERMIT y 4.AMENDED PERMIT ❑ 5 CHANGE OF INFORMATION E] 6 TEMPORARY SITE CLOSURE <br /> ❑ 7 PERMANENTLY CLOSED ON SITE <br /> ❑ 3 RENEWAL PERMIT (Specifi•reason-Cor local use only) (Spxify reason-for local use only) <br /> ❑8 TANK REMOVED 430 <br /> BUSINESS NAME(Same as FACILITY NAME or DBA-Doing Business As) FACILITY ID: PR#: <br /> ARCO STATION#5469* 3 FA0003601 PR0231861 <br /> LOCATION WITHIN SITE(Optional) 130 S WILSON WAY,STOCKTON 431 <br /> PHONE <br /> I.TANK DESCRIPTION(A scaled plot plan with the location of the UST system including buildings and landmarks shall be submitted to the local agency.) <br /> TANK ID# Tank#: 2 412 TANK MANUFACTURER 433 COMPARTMENTALIZED TANK <br /> ❑Yes ❑No 434 <br /> TA0186102 OWENS CORNING If"Yes",complete one page for each compartment. <br /> DATE INSTALLED(YEAR/MO) 435 TANK CAPACITY IN GALLONS a36 NUMBER OF COMPARTMENTS 437 <br /> 1/1/1988 12:00:OOAM 12,000 <br /> ADDITIONAL DESCRIPTION(For local use only) 438 <br /> CHNG PE FR 2380 TO 2360 PER LGB 3/13/00 LB <br /> IL TANK CONTENTS <br /> TANK USE 439 PETROLEUM TYPE a I„ <br /> ® 1.MOTOR VEHICLE FUEL ® I a.REGULAR UNLEADED ❑ 2.LEADED ❑ 5.JET FUEL <br /> (if marked complete Petroleum Type) <br /> ❑ lb.PREMHIM UNLEADED ❑ 3.DIESEL ❑ 6.AVIATION FUEL <br /> ❑ 2.NON-FUEL PETROLEUM ❑ Ic.MIDGRADE UNLEADED ❑ 4.GASOHOL ❑99.OTHER <br /> ❑ 3.CHEMICAL PRODUCT COMMON NAME(from Hazardous Materials <br /> ❑ Inventory page) 441CAS#(From Hazardous Materials Inventory page)) a4? <br /> 4.HAZARDOUS WASTE <br /> (Includes Used oil) <br /> ❑ 95.UNKNOWN <br /> III.TANK CONSTRUCTION <br /> TYPE OF TANK ❑ 1.SINGLE WALL ❑ 3.SINGLE WALL WITH ❑5.SINGLE WALL WITH INTERNAL BLADDER SYSTEM 44; <br /> (Check one item only) EXTERIOR MEMBRANE LINER ❑95.UNKNOWN <br /> ®2.DOUBLE WALL ❑ 4.SINGLE WALL IN VAULT ❑99.OTHER <br /> TANK MATERIAL-primary tank ❑ 1.BARE STEEL ® FIBERGLASS/PLASTIC ❑ 5.CONCRETE ❑95.UNKNOWN 444 <br /> (Check one item only) ❑ 2.STAINLESS STEEL ❑ STEEL CLAD W/FIBERGLASS ❑ S.FRP COMPTIBLE W/100%METHANOL <br /> REINFORCED PLASTIC(FRP) ❑ 99.OTHER <br /> TANK MATERIAL-secondary tank ❑ 1.BARE STEEL ❑ 3.FIBERGLASS/PLASTIC ❑ 5.CONCRETE ❑ 95.UNKNOWN 445 <br /> (Check one item only) ❑2.STAINLESS STEEL ❑ 4.STEEL CLAD W/FIBERGLASS ❑ 8.FRP COMPTIBLE W/I000%METHANOL <br /> REINFORCED PLASTIC(FRP) ❑ 10.COATED STEEL ❑ 99.OTHER <br /> ❑ 5.CONCRETE <br /> TANK INTERIOR LINING ❑ 1.RUBBER LINED ❑ 3.EPDXY LINING ❑5.GLASS LINING ❑95.UNKNOWN 446 DATE INSTALLED 447 <br /> OR COATING <br /> (Check one item only) ❑ 2 ALKYD LINING ❑ 4 PHENOLIC LINING ® 6 UNLINED F] 99.OTHER <br /> (For local use only) <br /> OTHER CORROSION ❑ 1 MANUFACTURING CATHODIC ® 3 FIBERGLASS REINFORCED PLASTIC ❑95 UNKNOWN 448 DATE INSTALLED 449 <br /> PROTECTION IF APPLICABLE PROTECTION <br /> (Check one item only) ❑ 4 IMPRESSED CURRENT ❑ 99 OTHER <br /> ❑ 2 SACRIFICIAL ANODE (For local use only) <br /> SPILL AND OVERFILL YEAR INSTALLE450 TYPE(local use only) 451 OVERFILL PROTECTION EQUIPMENT:YEAR INSTALLED 452 <br /> ' (Check all that apply) ® I SPILL CONTAINMENT X8.00 0� 7[j ALARM ❑ 3 FILL TUBE SHUT OFF VAL` <br /> ❑ 2 DROP TUBE 1vr5<BALL ❑ 4 EXEMPT <br /> 3 STRIKER PLATE FLOAT <br /> IV.TANK LEAK DETECTION(A description of the monitoring program shall be submitted to the local agency.) <br /> IF SINGLE WALL TANK(Check all that apply) 453 IF DOUBLE WALL TANK OR TANK WITH BLADDER 454 <br /> ❑ I VISUAL(EXPOSED PORTION ONLY) ❑5 MANUAL TANK GAUGING(MTG) (Check one item only) <br /> ❑ 2 AUTOMATIC TANK GAUGING(ATG) ❑6 VADOSE ZONE ❑ I VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑ 3 CONTINUOUS ATG ❑ 7 GROUNDWATER ®2 CONTINUOUS INTERSTITIAL MONITORING <br /> ❑4 STATISTICAL INVENTORY RECONCILIATION ❑ 8 TANK TESTING ❑3 MANUAL MONITORING <br /> (SIR)BIENNIAL TANK TESTING ❑ 99 OTHER <br /> V.TANK CLOSURE INFORMATION/PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) 455 ESTIMATED QUANTITY OF SUBSTANCE REMAINING 456TANK FILLED WITH INERT MATERIAL? 457 <br /> E]Yes <br /> ❑ No <br /> UPCF(12/99 revised) <br />
The URL can be used to link to this page
Your browser does not support the video tag.