EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BLACK DIAMOND
>
927
>
2800 - Aboveground Petroleum Storage Program
>
PR0515676
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/26/2019 10:42:05 AM
Creation date
3/19/2019 4:18:28 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0515676
PE
2832
FACILITY_ID
FA0003775
FACILITY_NAME
TIGER LINES INC
STREET_NUMBER
927
Direction
E
STREET_NAME
BLACK DIAMOND
STREET_TYPE
WAY
City
LODI
Zip
95240
APN
04903033
CURRENT_STATUS
01
SITE_LOCATION
927 E BLACK DIAMOND WAY
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
FRuiz
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
50
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SANJ O 1` Q U I `IA,II, Environmental Health Department <br /> COUNTY <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Fat-rch <br /> TIGER LINES INC 927 E BLACK DIAMOND WAY, LODI 14, 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 609 CFR 112.7(a)(3vi), 112.7(a4)Plan failed to adequately contain procedures for reporting a discharge. <br /> The Spill Prevention, Control, and Countermeasure(SPCC)Plan does not provide information and procedures to <br /> enable a person to adequately report a discharge. The name and contact information for the local CUPA,the San <br /> Joaquin County Environmental Health Department, is not provided in the SPCC plan. If a response plan was not <br /> submitted to the Regional Administrator,this information must be included in the SPCC Plan. Immediately amend <br /> the SPCC Plan to include this information and submit a copy of the revision to the EHD. <br /> This was corrected on site. <br /> This is a minor violation. <br /> 611 CFR 112.7(b) Plan failed to include a description of potential equipment failure or provide equivalence. <br /> Potential equipment failure and the resulting spill for tanks other than the 25,000 diesel tanks was not addressed in <br /> the Spill Prevention, Control, and Countermeasure(SPCC) Plan. The SPCC Plan must include a prediction of the <br /> direction, rate of flow, and total quantity of oil which could be discharged from the facility as a result of major <br /> equipment failure. Immediately amend the SPCC Plan to include this information and submit a copy of the revision <br /> to the EHD, or provide equivalence as allowed by 40 CFR 112.7(a)(2). <br /> This is a minor violation. <br /> 618 CFR 112.7(e), 112.8(c)(6) Failed to keep records of procedures, inspections,or integrity tests for three years. <br /> The inspection forms being used are not the forms provided by the Spill Prevention, Control, and Countermeasure <br /> (SPCC)Plan, and in some instances, do not contain the same information. Facility is using daily forms that address <br /> the overall condition of the tanks but do not have the detail of the forms required by the SPCC plan or that meet the <br /> requirements fo the STI SP-001 inspection forms.The STI SP-001 industry standard is referenced in the SPCC as <br /> the standard for the tanks. Inspections and tests must be conducted and stored in accordance with the written <br /> procedures developed for this facility in the SPCC Plan. Immediately begin conducting all inspections and tests in <br /> accordance with the procedures in the SPCC Plan, or amend the Plan and have it recertified by a Professional <br /> Engineer to accurately reflect the inspection procedures currently followed at the facility. <br /> This is a Class II violation. <br /> FA0003775 PR0515676 SCO01 03/14/2019 <br /> EHD 28-01 Rev.09/27/2018 Page 5 of 7 Aboveground Petroleum Storage Act OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.