My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2008 - 2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WILSON
>
130
>
2300 - Underground Storage Tank Program
>
PR0231861
>
COMPLIANCE INFO 2008 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2019 4:32:18 PM
Creation date
3/20/2019 3:57:24 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008 - 2015
RECORD_ID
PR0231861
PE
2361
FACILITY_ID
FA0003601
FACILITY_NAME
ARCO STATION #826951*
STREET_NUMBER
130
Direction
S
STREET_NAME
WILSON
STREET_TYPE
WAY
City
STOCKTON
Zip
95205-5561
APN
15502064
CURRENT_STATUS
01
SITE_LOCATION
130 S WILSON WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
248
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB, January 2002 <br />7. UNDER -DISPENSER CONTAINMENT UDC TE <br />Pageofd <br />STING _ <br />Test Method Developed By: ❑ UDC Manufacturer ❑ Industry Standard X Professional Engineer <br />❑ Other (Spec) <br />Test Method Used: ❑ Pressure ❑ Vacuum X Hydrostatic <br />❑ Other (Spec) <br />Test Equipment Used: Caldwell Level Change Indicator <br />Equipment Resolution: .002 <br />UDC Mall u(actL ei: <br />UDC # 1&2 <br />Bravo <br />UDC # 3&4 <br />Bravo <br />UDC # 5&6 UDC # 7&8 <br />I Bravo Bravo <br />UDC Material: <br />Fiberglass <br />Fiber lass <br />Fiberglass Fiberglass <br />UDC Depth: <br />35 %2" <br />35''/2" <br />31 W' 35 '/<" <br />Height from UDC Bottom to Top <br />of Highest Piping Penetration: <br />21" <br />16" <br />17" 16" <br />Height from UDC Bottom to <br />Lowest Electrical Penetration: <br />No Electrical <br />Penetrations <br />No Electrical <br />Penetrations <br />No Electrical No Electrical <br />Penetrations Penetrations <br />Condition of UDC prior to <br />testing: <br />Dry <br />Dry <br />Dry Dry <br />Portion of UDC Tested <br />Water Lever 23" <br />Water Level 18" <br />Water Level 18" Water Level 18 '/2" <br />Does turbine shut down when <br />UDC sensor detects liquid (both <br />oduct and water)?* <br />X Yes No 0 NA <br />X Yes No ❑ NA <br />X Yes No ❑ NA X Yes No ❑ NA <br />urbine shutdown response time <br />Not Alarmed <br />Not Alanned <br />Not Alarmed Not Alarmed <br />system programmed for fail- <br />fe shutdown?*XYes <br />r <br />❑No ❑NA <br />X Yes ❑ No ❑ NA <br />X Yes ❑ No ❑ NA X Yes ❑ No ❑ NA <br />as fail-safe verified to be <br />o erational?* <br />❑Yes X No ❑ NA <br />❑Yes X No ❑ NA <br />❑Yes X No ❑ NA ❑Yes X No [INA <br />Wait time between applying <br />water and starting test <br />5 Minutes <br />5 Minutes <br />5 Minutes 5 Minutes <br />Test Start Time: <br />11:50 <br />12:15 <br />12:50 11:55 <br />Initial Reading (Rl): <br />.001 <br />.001 <br />.001 .001 <br />Test End Time: <br />12:20 <br />12:45 <br />1:20 12:25 <br />Final Reading (RF): <br />.001 <br />.001 <br />.001 .001 <br />Test Duration: <br />30 Minutes <br />30 Minutes <br />30 Minutes 30 Minutes <br />Change in Reading (RF -R,): <br />0 <br />0 <br />0 0 <br />Pass/Fail Threshold or Criteria: <br />.005/30 Minutes <br />.005130 Minutes <br />.005/30 Minutes .005/30 Minutes <br />Test. Result: <br />X Pass ❑ Fail <br />X Pass 0 Fail <br />-X Pass ❑ Fail X Pass ❑ Fail <br />Was sensor removed for testing? <br />X Yes ❑ No [INA <br />X Yes ❑ No ❑ NA <br />X Yes ❑ No ❑ NA X Yes ❑ No ❑ NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />X Yes ❑ No ❑ NA <br />X Yes ❑ No ❑ NA <br />X Yes ❑ No ❑ NA X Yes ❑ No ❑ NA <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />' If the entire depth of the UDC is not tested, specify how much was tested. If the answer to a_y of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire UDC must be tested. (See SWRCB LG -160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.