My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2008 - 2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WILSON
>
130
>
2300 - Underground Storage Tank Program
>
PR0231861
>
COMPLIANCE INFO 2008 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2019 4:32:18 PM
Creation date
3/20/2019 3:57:24 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008 - 2015
RECORD_ID
PR0231861
PE
2361
FACILITY_ID
FA0003601
FACILITY_NAME
ARCO STATION #826951*
STREET_NUMBER
130
Direction
S
STREET_NAME
WILSON
STREET_TYPE
WAY
City
STOCKTON
Zip
95205-5561
APN
15502064
CURRENT_STATUS
01
SITE_LOCATION
130 S WILSON WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
248
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB, January 2002 <br />Page —�-- of� <br />Q Vifir T nircr" <br />- ----- _�_�_ ■� . vii 1[ill�ivli'.PI 1 3U1V11- 1 LN 11NG <br />Facility is Not Equipped With Fill Riser Containment Sumps <br />Fill Riser Containment Sumps are Present, but were Not Tested <br />Test Method Developed By: ❑ Sump Manufacturer ❑ Industry Standard X Professional Engineer <br />❑ Other (Spec) <br />Test Method Used: ❑ Pressure ❑ Vacuum X Hydrostatic <br />❑ Other (Specie) <br />Test Equipment Used: Caldwell Level Change Indicator <br />-� Fill Sump # 1 Fill Sump # 2mp <br />Sump Diameter: 42" 42"42„ <br />tEquipment Resolution: .002 <br /># 3 Fill Sump # <br />Sum De the <br />46" 53"48" <br />Height from Tank Top to Top of <br />Highest Piping Penetration: <br />22" 23" <br />22" <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />20 " 24" <br />20" <br />Condition of sump prior to <br />testin <br />Dry Dry <br />Dry <br />- <br />Portion of Sum Tested <br />Water Level 24 '/2" Water Level 26" <br />Water Level 24" <br />Sump Material: <br />Wait time between applying <br />water and startin test: <br />Fiberglass Fiberglass <br />5 Minutes 5 Minutes <br />Fiberglass <br />5 Minutes <br />Test Start Time: <br />10:05 10:50 <br />10:55 <br />Initial Readin (R,): <br />.001 .001 <br />.001 <br />Test End Time: <br />10:35 11:20 <br />11:25 <br />Final Readin (RF): <br />.001 .001 <br />.001 <br />Test Duration: <br />30 Minutes 30 Minutes <br />30 Minutes <br />Change in Reading (RF -R,): <br />0 0 <br />0 <br />Pass/Fail Threshold or Criteria: <br />.005/30 Minutes .005/30 Minutes <br />.005/30 Minutes <br />Test Result: <br />X Pass ❑ Fail X'Pass ❑ Fail <br />X Pass ❑ Fail <br />❑ Pass ❑ Fail <br />Is there a sensor in the sump? <br />X Yes ❑ No X Yes ❑ No <br />X Yes ❑ No <br />Yes ❑ No <br />Does the sensor alarm when <br />either product or water is <br />detected? <br />X Yes ❑ No ❑ NA X Yes ❑ No ❑ NA <br />X Yes ❑ No ❑ NA <br />Yes ❑ No ❑ NA <br />Was sensor removed for testing? <br />X Yes ❑ No ❑ NA X Yes ❑ No ❑ NA <br />X Yes ❑ No ❑ NA <br />Yes ❑ No ❑ NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />X Yes ❑ No ❑ NA X Yes ❑ No ❑ NA <br />X Yes ❑ No ❑ NA <br />Yes ❑ No ❑ NA <br />Comments — (include information on repairs made prior to testing and i•ecomniended follow-zrp for failed tests) <br />
The URL can be used to link to this page
Your browser does not support the video tag.