My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2016 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WILSON
>
130
>
2300 - Underground Storage Tank Program
>
PR0231861
>
COMPLIANCE INFO 2016 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2019 4:57:54 PM
Creation date
3/20/2019 4:29:01 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2018
RECORD_ID
PR0231861
PE
2361
FACILITY_ID
FA0003601
FACILITY_NAME
ARCO STATION #826951*
STREET_NUMBER
130
Direction
S
STREET_NAME
WILSON
STREET_TYPE
WAY
City
STOCKTON
Zip
95205-5561
APN
15502064
CURRENT_STATUS
01
SITE_LOCATION
130 S WILSON WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
142
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sogov.org/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />ARCO STATION #826951" <br />Facility Address: <br />1 130 S WILSON WAY, STOCKTON <br />Date: <br />January 24, 2017 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />105 <br />CCR 2632(d)(1) Failed to have an approved UST monitoring plan. <br />The monitoring plan is not current and/or not approved by the Environmental Health Department (EHD). Please <br />make the following changes to the UST Monitoring Plan for underground storage tank TA0186101. Beneath Pipe <br />Monitoring is Performed Using the Following Methods: change the Leak Sensor Model from 8484 to 323; and <br />beneath Training, change "No" to "Yes" for Personnel with UST Monitoring Responsibilities are Familiar with <br />Training Documents. The monitoring plans for underground storage tanks TA0186102 and TA0186103 have not <br />been entered into the California Environmental Reporting System (CERS). Immediately log into CERS, make the <br />necessary uploads and changes, and submit for review by the EHD. <br />This is a repeat violation, Class ll. <br />106 <br />CCR 2632(d)(2) Failed to have an approved UST response plan. <br />The response plan has not been uploaded to the California Environmental Reporting System (CERS). Immediately <br />log into CERS, upload the completed form, and submit for review by the EHD. Ensure a copy is available for <br />inspection at any time. <br />This is a minor violation. <br />107 <br />CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed. <br />An accurate UST Monitoring Site Plan was not submitted. A site plan must be submitted identifying the locations <br />where monitoring will be performed. Immediately log into the California Environmental Reporting System (CERS) at <br />http://cers.calepa.ca.gov/ and upload a copy of the UST Monitoring Site Plan. <br />This is a minor violation. <br />201 <br />CCR 2712(b) Failed to maintain alarm logs and/or records of follow up actions. <br />The secondary containment test results for 5/28/14 were not found on site. The facility failed to document the L2:87 <br />master turbine STP sump sensor out alarm on 4/11/16; the Q1:91 PLLD shutdown and Gross Line Fail on 2/9/16 <br />and 2/17/16 and the Q2:87 PLLD shutdown and Gross Line Fail on 2/22/16 on the daily alarm logs. Records shall <br />be maintained on site for at least three years. Monitoring records include: (1) date and time of all monitoring or <br />sampling; (2) monitoring equipment calibration and maintenance records; (3) results of any visual observations; (4) <br />results of sample analysis performed a lab or in the field; (5) logs of all readings of gauges or other monitoring <br />equipment, ground water elevations, or other test results; (6) results of inventory readings and reconciliations. <br />Immediately locate and maintain all maintenance and monitoring records for the last three years on site and submit <br />copies to the EHD. <br />This is a repeat violation, Class II. <br />204 <br />CCR 2712(1) Current monitoring plan approved by the EHD not found on site. <br />An approved copy of the monitoring plans were not available for inspection. A copy of these plans shall be <br />accessible on site at all times. Immediately locate and retain a copy on site. <br />This is a repeat violation, Class Il. <br />FA0003601 PR0231861 SCO01 01/24/2017 <br />EHD 23-01 Rev. 09/22/16 Page 4 of 6 Underground Storage Tank Program OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.