My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2016 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WILSON
>
130
>
2300 - Underground Storage Tank Program
>
PR0231861
>
COMPLIANCE INFO 2016 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2019 4:57:54 PM
Creation date
3/20/2019 4:29:01 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2018
RECORD_ID
PR0231861
PE
2361
FACILITY_ID
FA0003601
FACILITY_NAME
ARCO STATION #826951*
STREET_NUMBER
130
Direction
S
STREET_NAME
WILSON
STREET_TYPE
WAY
City
STOCKTON
Zip
95205-5561
APN
15502064
CURRENT_STATUS
01
SITE_LOCATION
130 S WILSON WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
142
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
- San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sigov.org/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />ARCO STATION #826951 <br />Facility Address: <br />1 130 S WILSON WAY, STOCKTON <br />Date: <br />January 24, 2017 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />205 <br />CCR 2712(1) Failure to have an approved UST response plan available onsite. <br />An approved copy of the response plan was not available for inspection. A copy of the plan shall be accessible on <br />site at all times. Immediately locate and retain a copy on site. <br />This is a minor violation. <br />209 <br />CCR 2715(c) Designated operator did not inspect all required items and/or the inspection reports not completed. <br />The designated operator failed to check and note the correct test dates for the monitoring system certification, spill <br />container, line leak detector and secondary containment testing on the May through December 2016 designated <br />operator monthly inspection reports. Instead of entering 1/12/16 for the monitoring system certification, spill <br />container and line leak detector testing, the designated operator entered 1/27/16; and instead of entering 5/28/14 for <br />the secondary containment testing, the designated operator entered 3/25/14. The designated operator listed <br />1/15/15 for the line leak detector and spill container testing on the 4/22/16 designated operator monthly inspection <br />report instead of 1/12/16 for these tests, and listed 1/15/15 for the monitoring system certification, line leak detector, <br />and spill container testing on the 2/26/16 designated operator monthly inspection report instead of 1/12/16 for these <br />tests. The designated operator did not address the Q1:91 PLLD shutdown and Gross Line Fail alarms that occurred <br />on 8/28/16 and 8/29/16 on the 9/20/16 designated operator monthly inspection report. The designated operator did <br />not document the T1:87 Master leak alarm that occurred on 3/14/16 and the sudden loss alarm that occurred on <br />3/3/16 on the 3/28/16 designated operator monthly inspection report. The designated operator did not complete <br />items 1 through 4 on the designated operator monthly inspection report for 8/18/16 and did not complete items 6, 7, <br />and 8 on the designated operator monthly inspection report for 2/26/16. The designated operator shall check that <br />all required testing and maintenance for the UST system have been completed and document the dates they were <br />done. Ensure that designated operators performing monthly inspections at this facility are including all of the <br />required information on the reports. <br />This is a repeat violation, Class II. <br />211 <br />CCR 2715(f) Designated operator employee training not performed or log not kept. <br />The designated operator employee training for 2016 did not include the Hire Date of the employees The designated <br />operator shall train facility employees for which he or she is responsible in the proper operation and maintenance of <br />the UST system once every 12 months. The training shall include, but is not limited to: <br />1. Operation of the UST system in a manner consistent with the facility's best management practices <br />2. Employee's role with regard to monitoring equipment as specified in the facility's monitoring plan <br />3. Employee's role with regard to spills and overfills as specified in the facility's response plan <br />4. Name of the contact person(s) for emergencies and monitoring equipment alarms <br />Ensure that employees have been trained by the designated operator, maintain the list on site, and submit a copy of <br />the training records to the EHD. <br />This was corrected on site. <br />This is a minor violation. <br />FA0003601 PR0231861 SCO01 01/24/2017 <br />EHD 23-01 Rev. 09/22/16 Page 5 of 6 Underground Storage Tank Program OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.