Laserfiche WebLink
San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.orq/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Facility Address: <br />Date: <br />ARCO STATION #826951 <br />130 S WILSON WAY, STOCKTON <br />January 24, 2017 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS Il, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />306 <br />CCR 2630(d) Monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity. <br />The 91 -product submersible turbine pump sump 323 sensor was not located at the lowest point of the sump and not <br />located to detect a leak at the earliest opportunity. Monitoring equipment shall be maintained to be able to detect a <br />leak at the earliest possible opportunity. The sensor was relocated to the lowest point of the sump by the service <br />technician. Ensure that all monitoring equipment is maintained to detect a leak at the earliest opportunity. <br />This was corrected on site. <br />This is a Class II violation. <br />315 <br />HSC 25291(e) Water in secondary containment not removed, analyzed, and properly disposed of (pre -Jul 2003). <br />Liquid was observed in the vent sump. If water could enter into the secondary containment by precipitation or <br />infiltration, it must be removed and disposed of properly. The service technician removed approximately two cups of <br />liquid from the vent sump. Ensure that all sumps and annular spaces are maintained free of liquid. <br />This was corrected on site. <br />This is a minor violation. <br />320 <br />CCR 2635(b)(2) Overfill prevention system not present or failed to meet overfill requirements. <br />The outside control switch for the overfill alarm used as the overfill prevention system is not currently functional. <br />Immediately have the control switch for the overfill alarm repaired or replaced by a properly licensed, trained, and <br />certified contractor. This facility can not get fuel delivery until this control switch has been repaired/replaced. <br />This is a Class II violation. <br />Overall Inspection Comments: <br />Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br />documenting the corrective actions that have been or will be taken for each violation, and any supporting <br />paperwork, by February 23, 2017. <br />Please be aware that as of January 1, 2014, facility operators are required to upload the following UST program <br />documents into the California Environmental Reporting System (CERS): UST Monitoring Site Plan, UST <br />Certification of Financial Responsibility, UST Response Plan, UST Letter from Chief Financial Officer (if <br />applicable), and the Owner Statement of Designated Operator Compliance. The UST Owner/Operator: Written <br />Agreement, if applicable, can be stored at the facility or uploaded into CERS. <br />AFTER THE COMPLIANCE DATE, EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING <br />THIS FACILITY BACK INTO COMPLIANCE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br />Received by: Date: January 24, 2017 <br />Inspector: <br />Inspector Phone: <br />Printed Name and Title: <br />VICKI MCCARTNEY, Senior REHS <br />(209) 468-9852 <br />Parminder Mashiana, Owner <br />FA0003601 PR0231861 SCO01 01/24/2017 <br />EHD 23-01 Rev. 09/22/16 Page 6 of 6 Underground Storage Tank Program OIR <br />