Laserfiche WebLink
r � ' <br /> E NVI 01N MEN' L. HEALTH OEPARTMENT <br /> OP�U!N'• <br /> 1�"'„C <br /> =� 51 SAN JOAQUIN COUNT' <br /> _ ' <br /> Program ram Coordinators <br /> Donna K. Reran, R.E.H.S. S <br /> Director 304 East Weber Avenue,Third Floor Carl Borgman,R.E.H.S. <br /> m• `' '• gg' <br /> Mike Huggins,R.E.H.S.,R.D.I. <br /> Laurie A. Cotulla,R.E.H.S. Stockton,California 95202-2708 <br /> C4� FOF�`P Assistant DirectorTelephone: (209)468-3420 Margaret Lagorio, R.E.H.S. <br /> Robert McClellon,R.E.H.S. <br /> Fax: (209)464-0138 Jeff Carruesco,R.E.H.S. <br /> Website:www.sjgov.org/ehd/ Kasey Foley,R.E.H.S. <br /> December 18, 2006 <br /> Narin Tith <br /> 1908 E 11" st <br /> Stockton,CA 95206 <br /> Re: Proposed TC's Dalton Club <br /> 13464 E Hwy 88, Lockeford CA <br /> Dear: Owner/Operator/Requestor <br /> This letter will indicate Environmental Health Department approval of drawings <br /> submitted for the proposed"TC's Dalton Club" subject to the following conditions: <br /> 1) The floor surfaces in all areas in which food is prepared, packaged, open food storage, <br /> utensil washing areas, refuse storage,janitorial areas, and all restroom.s and employee <br /> change areas shall be smooth and of durable construction and nonabsorbent material <br /> which is easily cleaned. These floor surfaces shall be coved at the juncture at the <br /> floor and wall with a three-eighths (3/8) inch minimum radius coving and shall extend <br /> up the wall at least four(4) inches. Rubber or vinyl top set base is not permitted in <br /> these areas. CURFFL 114150 This section applies to the area where the mop sink <br /> and water heater will be installed. <br /> 2) Dry storage is not indicated on the plans. Owner, Narin Tith, came in the office to <br /> indicate where dry storage will be used. There must be 144 sq. ft. of dry storage. Dry <br /> storage indicated on plans-redline change. <br /> 3) All sinks must be 12" apart or an 18�" splashguard is required. <br /> 4) Ventilation hood installation must meet sections 402.4 and 508.6 of UMC. Provide <br /> 1-11 specification sheets for the ventilation hood. <br /> 5) All walls and ceilings of all rooms, must be cleanable and have a Light Reflectance <br /> Value (LRV) of 70% or greater. <br /> 6) Provide an adequate supply of hot water to meet the peak demands of all fixtures <br /> utilizing hot water. CURFFL 114095 The instantaneous water heater must have a <br /> water recovery rate of 8 GPM at 60°F rise. The proposed water heater is too small. <br />