Laserfiche WebLink
TRAVEL CENTER LIGHTING FIXTURE SCHEDULE Documgneerintspregaredbycorare to be used �o <br /> States EngiCORE STATES <br /> neering Q FERG <br /> only for the specific project and �� US <br /> LAMP DATA specific use for which they are <br /> intended. Any extension of use to <br /> TAG DESCRIPTION MANUFACTURER CATALOG NUMBER MOUNTING VOLT VA QTY LAMP TYPE REMARKS other projects, by owner or any 18497 <br /> 4' FLUORESCENT STRIP other party, without the expressed, <br /> Al 4' FLUORESCENT STRIP COLUMBIA CS4-254—EPU SURFACE 120 108 2 54W/T5HO OWNER SHALL PROVIDE PROGRAMMED written consent of Core States <br /> START BALLAST Engineering is done at the user's F� <br /> own risk. If used in a way other 1700 Industrial Drive,suite B G R O U P ,qT FCTRIC <br /> than that specifically intended, user Rogers,AR 72756 U CAL�� ,t`I <br /> will hold Core States Engineering Phone(479)986-4400 01 <br /> harmless from all claims and losses. FAX(479)986-4401 <br /> GENERAL ELECTRICAL NOTES <br /> 1. CONDUIT SHALL NOT BE SURFACED MOUNTED ON CANOPY COLUMNS WITH THE EXCEPTION OF <br /> RECEPTACLES. <br /> 2. ALL WIRING METHODS SHALL COMPLY WITH NEC ARTICLE 514. <br /> 3. COORDINATE WITH PROCESS PIPING DRAWINGS AND VEEDER—ROOT SHOP DRAWINGS. <br /> ES1 ` i <br /> 4. SENSOR CABLING SHALL COMPLY WITH VEEDER—ROOT SPECIFICATIONS. <br /> ------------------------------------------------ <br /> 5. EC SHALL CLEARLY LABEL ALL CONDUIT FROM THE CONTROL CABINET AND ELECTRICAL ROOMS <br /> L— TO INCLUDE THE CONDUITS TERMINATION POINT IN THE FIELD. CONDUIT SHALL ALSO BE <br /> 0 <br /> O z LABELED AT FINAL DESTINATION AS TO WHERE IT ORIGINATES. <br /> I I � <br /> 1 II <br /> g - KEYED NOTES <br /> 0 0 <br /> sav sav sav Isar! s �sav �sav sav sav �sav �sav �sav �sav < <br /> ___________________ _____________ ____ O CONTRACTOR SHALL PROVIDE NEW 100A, 208V, 3—POLE BREAKER TO FEED NEW BIO—DIESEL <br /> — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — \ BUILDING PANEL "P" ALONG WITH ALL THE NECESSARY CONDUIT,FITTINGS AND CONDUCTORS. <br /> O �\ � MAINTAIN REQUIRED WORKING CLEARANCE IN—FRONT OF PANEL OF 36" DEEP BY 30" WIDE BY <br /> s 0 78" TALL, ALSO MAINTAIN FREE SPACE ABOVE ELECTRICAL PANEL TO STRUCTURAL CEILING. <br /> ° O \\0 ALL WIRING METHODS SHALL COMPLY WITH NEC ARTICLE 514. REFERENCE PROCESS DRAWINGS. <br /> \ g O COORDINATE WITH PROCESS PIPING DRAWINGS AND VEEDER—ROOT SHOP DRAWINGS. <br /> L --4 1 <br /> El -tEl- 11 (\\O O FIXTURE SHALL BE PROVIDED WITH 120V BALLAST. COORDINATE EXACT LOCATION WITHEl <br /> a <br /> O ARCHITECTURAL CEILING PLAN. <br /> z <br /> 1 I I <br /> \ \ O EC SHALL CLEARLY LABEL ALL CONDUIT FROM THE CTS AND ELECTRICAL ROOMS TO INCLUDE THE <br /> \\\O CONDUITS TERMINATION POINT IN THE FIELD. CONDUIT SHALL ALSO BE LABELED AT FINAL <br /> O i^ DESTINATION AS TO WHERE IT ORIGINATES. <br /> % <br /> PROVIDE 208V CONNECTION TO ELECTRIC WALL HEATER. COORDINATE EXACT LOCATION IN FIELD I1 I1 <br /> \\\ O PRIOR TO ROUGH—IN. IuL, <br /> ` 7 CONTRACTOR SHALL MAKE CONNECTION FROM MOTOR CONTROLLER TO BIO—DIESEL PUMP MOTOR. <br /> CONTRACTOR SHALL PROVIDE JUNCTION BOX AND RACEWAY WITH PULL—STRING FOR REMOTE <br /> ES1 8 THERMOSTAT. COORDINATE BOX SIZE,RACEWAY SIZE AND LOCATION WITH INSTALLING CONTRACTOR. <br /> CONTRACTOR SHALL PROVIDE CONNECTION TO EXISTING TLS-450 FUELING CONSOLE FOR LOW <br /> LEVEL ALARM SHUT—OFF. SEE SHEET ES4 FOR MORE INFORMATION. COORDINATE CABLE CABLE <br /> \ �� TYPE WITH MANUFACTURER'S INSTRUCTIONS. ALSO PROVIDE COMMUNICATIONS CABLING FOR <br /> ° \\\ O PROCESS MONITORING. COORDINATE WITH OWNER REPRESENTATIVE FOR CABLING TYPE AND FINAL NN <br /> \% �� _ / CONNECTION POINTS FOR THE COMMUNICATIONS PORTION. L� <br /> LTJ o <br /> CONNECT TO MOTOR CONTROLLER. COORDINATE EXACT LOCATION IN FIELD PRIOR TO ROUGH IN. Q <br /> SEE SHEET ES4 FOR MORE INFORMATION. 0 Q0 <br /> \ 3 11 PROVIDE CONNECTION TO EXHAUST FAN. <br /> I <br /> 3 W N-) <br /> PROVIDE CONNECTION TO BIO—DIESEL CONTROL PANEL. U w <br /> Z J 0 <br /> QVLLJ <br /> � � Q <br /> °C > <br /> S TE PLAN E CAE W � UO <br /> 3 1" — 100' _0$t KEYED NOTES FOR POSITIVE SHUTDOWN W Q Q <br /> SUMP SENSOR SHALL BE WIRED FOR POSITIVE SHUTDOWN OF TRUCK DIESEL STP UPON ALARM. vJ J <br /> REFER TO VEEDER—ROOT INSTALLATION MANUAL FOR CORRECT WIRING SEQUENCE FOR POSITIVE W = Q <br /> SHUTDOWN. <br /> SENSOR LEGEND <br /> 4 -------------------------------- 0 z O <br /> 0�-------------------------- <br /> �S INTERSTITTAL SENSOR <br /> O <br /> LV TANK LEVEL SENSOR In <br /> ---------------- i MW MONITORING WELL SENSOR <br /> SP SUMP SENSOR <br /> ° MAINTAIN WORKING CLEARANCES HS HYDROSTATIC SENSOR <br /> FOR PANEL "P" PER NEC. PS PIPING SENSOR <br /> P- 10 P NEL o CONDUIT ROUTING SCHEDULE <br /> I <br /> 12 1 P 11 Co <br /> 1" CONDUIT TO FUEL MONITORING WIREWAY. <br /> J � EE <br /> P- 12 C� CONDUIT TO EXISTING 120/208V DISTRIBUTION PANEL IN ELECTRICAL ROOM, FEED FOR PANEL"P" <br /> REFERENCE SHEET ES3-1 <br /> ° 0 SPHS <br /> j P-4 C� 1" CONDUIT TO FUEL MONITORING WIREWAY FOR LOW LEVEL ALARM SHUT OFF AND <br /> ® ® 6 a COMMUNICATIONS. <br /> 1" SPARE CONDUIT WITH 2O0LB PULL STRING TO ELECTRICAL ROOM, CONDUIT SHALL BE <br /> ° STUBBED UP 12" AFG AND CAPPED WITH WEATHER TIGHT SEAL. J <br /> W <br /> i7 -s I 3 <br /> • I 33 C� 1" CONDUIT FOR 2 CAT5 CABLES WITH RJ 45 CONNECTORS TO BE PULLED FOR COMMUNICATION m <br /> 4 a 0 SPHS LV <br /> NOTES TO CONTRACTOR <br /> a 1. CONTRACTOR SHALL VISIT SITE AND FAMILIARIZE HIS/HERSELF WITH THE EXISTING CONDITIONS. m <br /> O <br /> ° 2. EC SHALL CLEARLY LABEL ALL CONDUIT FROM THE CONTROL CABINET AND ELECTRICAL ROOMS M < <br /> 1 a TO INCLUDE THE CONDUITS TERMINATION POINT IN THE FIELD. CONDUIT SHALL ALSO BE I <br /> O SPHS 0 SP HS PS LABELED AT FINAL DESTINATION AS TO WHERE IT ORIGINATES. N <br /> I M <br /> 3. PUMP ROOM IS A CLASS II DIV II ENCLOSURE. EXPLOSION PROOF FITTING AND DEVICES NOT o <br /> REQUIRED. EC TO PROVIDE SEAL—OFFS AT ALL CONDUITS ENTERING PUMP ROOM. <br /> o I <br /> is Q W <br /> ° V � i <br /> N <br /> P-8 <br /> COPYRIGHT, <br /> J TRAVEL(UNPUBLISHED) <br /> PLAZA <br /> 0 <br /> CONFIDENTIAL <br /> THIS DRAWING IS CONFIDENTIAL <br /> 4 ° NO USE OR DISCLOSURE OF THIS DRAWING <br /> IS PERMITTED, EXCEPT AS EXPRESSLY <br /> AUTHORIZED BY FLYING J TRAVEL PLAZA <br /> SFEET: <br /> EO - DESEL PUMP ROOM ETRUCK TANK FARM PLAN E <br /> - S1 <br /> 2 NTS 1" = 10' —0" <br /> 0 15 <br />