Laserfiche WebLink
ENVIRONMENTAL HEALTH DEPARTMENT <br /> SAN JOAQUIN COUNTY <br /> Donna K. Heran, R.E.H.S. <br /> Program Coordinators <br /> Director 304 East Weber Avenue,Third Floor Carl Borgman, R.E.H.S. <br /> p Laurie A. Cotulla, R.E.H.S. Stockton,California 95202-2708 Mike Huggins, R.E.H.S., R.D.I. <br /> ..,.... Assistant Director Margaret Lagorio, R.E.H.S. <br /> �,F o R� Telephone: (209)468-3420 <br /> Robert McClellon, R.E.H.S. <br /> Fax: (209) 464-0138 Jeff Carruesco, R.E.H.S. <br /> Website:www.sjgov.org/ehd/ Kasey Foley, R.E.H.S. <br /> DECEMBER 21, 2006 <br /> ATTN: JASWINDER SINGH <br /> 8104 POWELL DRIVE <br /> STOCKTON, CA 95212 <br /> RE: LAKESIDE MARKET <br /> 2233 GRAND CANAL BLVD # 201 <br /> STOCKTON, CA 95207 <br /> Dear Mr. SINGH: <br /> The following items need to be corrected as part of the final approval prior to issuance of a <br /> permit to operate based on plans submitted prior to San Joaquin County Environmental Health <br /> Department in accordance with the California Health and Safety code requirements; <br /> 1. A doorway a minimum of 32"X80" needs to be constructed to create a direct connection <br /> from the store to the utensil washing room. <br /> 2. The utensil washing room base coving needs to be replaced with smooth durable <br /> nonabsorbent material that has a % radius coving that extends up the wall at least 4 <br /> inches. <br /> 3. The mop sink needs to be a low profile type if left in the utensil washroom to prevent <br /> cross contamination. The existing shower in the restroom could be converted to a mop <br /> sink with hot/cold water if done correctly in lieu of the mop sink in the utensil washroom. <br /> 4. The restroom rubber base vinyl top is not acceptable and will require removing and <br /> creating a floor wall juncture % radius coving with appropriate material to extend up the <br /> wall 4" similar to item #2. <br /> 5. No dry storage is depicted. The room between the walk in coolers will need the slated <br /> wall material removed and replaced with smooth durable and light colored material. <br /> Adequate dry storage must be provided equivalent to 96 linear feet of 18 inch deep (144 <br /> sq ft) that is smooth, durable, nonabsorbent, and cleanable. <br /> 6. This facility must supply a commercial water heater that will meet the peak calculated <br /> hourly demand of 40 gallons per hour and a minimum 6kw. The water heater must have <br /> a recovery rate equal to or greater than the peak hourly demand at a 60 degree F rise. <br /> CURFFL 114095 <br /> - l - <br />