Laserfiche WebLink
INDIVIDUAL TANK INFORMATION AND EST RESULTS <br /> i Tb <br /> TEST DATE:07/29/99 8900 SHOAL CREEK, BUILDING 200 WORK ORDER NUMBER2209536 <br /> CLIENT:ARCO PRODUCTS COMPANY AUSTIN,TEXAS 78757(512)451-6334 SITE:ARCO <br /> Tank ID: 12K 3 Tank manifolded: NO Bottom to top fill in inches: 179.0 <br /> Product: PREMIUM Vent manifolded: NO Bottom to grade in inches: 185.0 <br /> Capacity in gallons: 11,849 Vapor recovery manifolded: YES Fill pipe length in inches: 61.0 <br /> Diameter in inches: 118.00 Overfill protection: YES Fill pipe diameter in inches: 4.0 <br /> Length in inches: 253 Overspill protection: YES Stage I vapor recovery: DUAL <br /> Material: DW FIBERG Installed: Stage II vapor recovery: BALANCE <br /> CP installed on. <br /> COMMENTS <br /> # �d.:>7s'!3E'll<z«..:::...:.:::.:..:..:: ;. <br /> E :::»>::::,:::«>:::>::>:::>:: .' ::4 .............................._..........__............. <br /> Start(in) End(in) <br /> New/passed Failed/replaced New/passed Failed/replaced <br /> Dipped Water Level: 0.00 0.00 <br /> L.D.#1 L.D.#1 L.D.#2 L.D.#2 <br /> Dipped Product Level: 36.00 36.00 <br /> Probe Water Level: 0.000 0.000 Make: RED TAQ�T <br /> Ingress Detected: Water N Bubble N Ullage N <br /> Model: L.L.D. <br /> S/N: <br /> Test time: 14:12-16:03 Open time in sec: <br /> Inclinometer reading: 0.00 Holding psi: 25 <br /> VacuTect Test Type: Multiple tanks Resiliency cc: NOT <br /> VacuTect Probe Entry Point: Fill est leak rate ml/m: 189.0 TESTED <br /> Pressure Set Point: -0.50 Metering psi: <br /> Tank water level in inches: 0.00 Calib. leak in gph: 3.00 <br /> Water table depth in inches: Results: PASS <br /> Determined by (method): <br /> Result: PASS COMMENTS <br /> COMMENTS <br /> :.. :::::::::::..........::.:::.:::::::::::::::::.::::::::::::::::::::.................:.:::::. <br /> :::.::::::::.:......................:..::.... 3' .........................::::::::.::.:::::..........,,:::..:::::::::::.:............ ....,:.:::.:::.:::::::::.::.............::::::.:::.:::::: :::::..::...:.:.............. ................. <br /> Material: DW FIBERG <br /> Diameter(in): 2.0 <br /> Length (ft): 100.0 <br /> Test psi: 50 <br /> Bleedback cc: 0 <br /> Test time(min): 30 NOT NOT NOT <br /> Start time: 16:10 TESTED TESTED TESTED <br /> End time: 16:40 <br /> Final gph: 0.000 <br /> Result: PASS <br /> Pump type: PRESSURE <br /> Pump make: RED JACKET <br /> COMMENTS Impact Valves Operational: YES <br /> Draft 07/30/1999 09:27 MSHAW <br />