6 <br />INSTALLATION, CONT’D.: REAR PANEL REMOVAL / SHIMMING / SEALING <br />Refrigeration Assembly <br />Rear View Wicking Material <br />To Be Held in <br />Place With <br />Prongs <br />Use shims to level case. <br />After case is in position and shimmed, it must be <br />sealed to floor with continuous bead of silicone caulk <br />to prevent entry or leakage of liquid or moisture. <br />See below-right illustration of frame support rails. <br />--- Case Rear View / Rear Panel Removed (Shown Below) --- <br />Rear Panel <br />Screw Locations <br />Power Cord <br />Route <br />Rear <br />Panel <br />Caution! Risk of electric shock! Only certified <br />electricians are to access electrical components. <br /> <br />3. Rear Field Access <br />Note: Access to case rear AFTER installation is <br />extremely limited (without pulling case out from wall). <br />To access components at rear of case, remove rear <br />panel retaining screws (see illustration below). Lift <br />panel up and off case rear. <br />While rear panel is removed, (and before moving case <br />into position), check that evaporator pan is positioned <br />directly under condensate drain. <br />Also, before moving case into position, plug cord into <br />wall (or field wire). See illustration at right. <br />Caution! To assure proper airflow, replace rear panel <br />when done. <br />Slide case into proper merchandising location. <br /> <br />4. Frame Support Rails Must Be Shimmed and <br />Sealed To Floor <br /> <br />Shims will be provided for all cases that have frame <br />support rails. <br />Note: After case is in position and shimmed, it must be <br />sealed to floor with continuous bead of silicone caulk to <br />prevent entry or leakage of liquid or moisture. <br /> <br />4” x 4” Field Wiring Box <br />Location (For Hardwiring) <br /> <br />Power Cord <br />& Plug