Page __�_ of 7 <br />6- PIPING SITMP TESTING <br />Test Method Developed By: ❑ Sump Manufacturer ® Industry Standard ❑ Professional Engineer <br />❑ Other (Specify) <br />Test Method Used: ❑ Pressure ❑ Vacuum ® Hydrostatic <br />❑ Other (Specify) <br />LEquipment Used: Wayne Perry Inc. v " I Vjr-_S2. <br />Equipment Resolution: .0007" <br />Sump Diameter: <br />Sump # $ . /N <br />Sump # $ 7 �t <br />Sump # q <br />Sump # <br />5Z 0 11S� <br />Sump Depth: <br />S .r <br />Sump Material:1-go, <br />F amu" tas <br />Ere - E /I <br />Mize TW4 01 a a M., <br />�'I81111t 11 <br />Height from Tank Top to Top of <br />Highest Piping Penetration: <br />3-a(1 „ <br />311, 11» <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />K <br />2,z <br />9 <br />Condition of sump prior to testing: <br />p 0_0 <br />t I <br />t <br />Portion of Sum Tested <br />Sump <br />2" ABOVE HIGHEST <br />PIPING PENETRATION <br />2" ABOVE HIGHEST <br />PIPING PENETRATION <br />2" ABOVE HIGHEST <br />PIPING PENETRATION <br />2" ABOVE HIGHEST <br />PIPING PENETRATION <br />Does turbine shut down when <br />sump sensor detects liquid (both <br />product and water)?` <br />❑ Yes ❑ No ® NA <br />❑ Yes ❑ No ®NA <br />❑ Yes ❑ No ®NA <br />❑ Yes ❑ No M NA <br />Turbine shutdown response time <br />NA <br />NA <br />NA <br />Is system programmed for fail-safe <br />shutdown?* <br />❑ Yes ❑ No ® NA <br />❑ Yes ❑ No ® NA <br />❑ Yes ❑ No ® NA <br />❑ Yes ❑ No ®NA <br />Was fail-safe verified to be <br />operational?* <br />❑ Yes ❑No ® NA <br />❑ Yes ❑No ® NA <br />❑ Yes ❑No ® NA <br />❑ Yes ❑ No Z NA <br />Wait time between applying <br />pressure/vacuum/water and starting <br />test: <br />15 Minutes <br />15 Minutes <br />15 Minutes <br />15 Minutes <br />Test Start Time: <br />5: q1, <br />S-.- '1 <br />:570 <br />Initial Reading (RI): <br />19 AP q11 <br />11-G71-7-7411 <br />Test End Time: <br />6:01 <br />5-:96 <br />(o ; 05 <br />Final Reading (RF): <br />$ , <br />1. SI Z <br />z O <br />Test Duration: <br />15 Min <br />15 Min <br />15 Min <br />15 Min <br />15 Min <br />15 Min <br />15 Min <br />15 Min <br />Change in Reading (RF -RI): <br />0. p <br />0,60D51 <br />a 001 L <br />Pass/Fail Threshold or Criteria: <br />-0.0020 <br />-0.0020 <br />-0.0020 <br />-0.0020 <br />-0.0020 <br />-0.0020 <br />-0.0020 <br />-0.0020 <br />Test Result: <br />Pass ❑ Fail <br />� -Passl ❑Fail <br />®Pass ❑Fail : <br />p Pass OF <br />Was sensor removed for testing? <br />❑ Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />[Was sensor properly replaced and <br />ified functional after testing? <br />❑ Yes ❑ No ❑ NA <br />ElYes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />❑ Yes ❑ No 11NA <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />BP/Arco #02186 <br />3212 N California <br />Stockton, CA. 95204 <br />N04731 — SB 989 Testing <br />