Laserfiche WebLink
• Annex C provides sample checklists that the owner/operator can use when developing <br /> inspection intervals and specific procedures for internal and external inspections of both in- <br /> service and out-of-service tanks. <br /> • Annex D focuses on the requirements for authorized inspector certification. Certification of <br /> authorized tank inspectors,which is valid for three years from the date of issue, requires the <br /> successful completion of an examination, as well as a combination of education and experience. <br /> • Annex E has been removed, and is purposefully left blank. <br /> • Annex F summarizes the non-destructive examination (NDE) requirements for reconstructed <br /> and repaired tanks. <br /> • Annex G discusses the qualification of tank bottom examination procedures and personnel. <br /> • Annex H provides guidance for performing a similar service assessment to establish inspection <br /> intervals for tanks for which corrosion rates have not been directly measured. <br /> • Annex S covers the requirements for austenitic stainless steel storage tanks, constructed in <br /> accordance with API 650,Appendix S,that differ from the basic rules in the rest of API 653. <br /> Technical inquiries regarding the use of the standard can be made through API's Web site <br /> (www.api.org). <br /> 7.7.2 STI Standard SP001 - Standard for the Inspection of Aboveground Storage Tanks <br /> STI Standard SP001—Standard for the Inspection of Aboveground Storage Tanks(STI SP001)154 provides <br /> inspection and evaluation criteria to determine the suitability for continued service of aboveground storage <br /> tanks until the next scheduled inspection. STI SP001 applies to the inspection of aboveground storage tanks, <br /> including shop-fabricated tanks,field-erected tanks, and portable containers, as defined in the standard, as well <br /> as their containment systems.The inspection and testing requirements for field-erected tanks are covered <br /> separately in Appendix B of the standard. Specifically,the standard applies to ASTs storing stable,flammable, <br /> and combustible liquids at atmospheric pressure with a specific gravity less than approximately 1.0, and those <br /> storing liquids with operating temperatures between ambient temperature and 200 degrees Fahrenheit <br /> (93.3°C).15s At a minimum,the following tank components shall be inspected (as applicable): primary and <br /> secondary tanks, supports, anchors, foundation and external supports, gauges and alarms, insulation, <br /> appurtenances, normal and emergency vents, release prevention barriers, and spill control systems. <br /> After providing general information and definitions, Section 3 of the standard addresses safety <br /> considerations, and Section 4 addresses AST inspector qualifications. <br /> iso STI Standard SP-001,"Standard for the Inspection of Aboveground Storage Tanks,"5th Edition September 2011. <br /> 155 Given this operating range,the standard may not apply to certain tanks such as those containing asphalt cement. <br /> SPCC GUIDANCE FOR REGIONAL INSPECTORS 7-64 <br /> December 16, 2013 <br />