My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TILLIE LEWIS
>
1477
>
2800 - Aboveground Petroleum Storage Program
>
PR0523160
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/28/2019 10:34:21 AM
Creation date
3/26/2019 4:50:54 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0523160
PE
2832
FACILITY_ID
FA0010602
FACILITY_NAME
WILLIAMS TANK LINES
STREET_NUMBER
1477
STREET_NAME
TILLIE LEWIS
STREET_TYPE
DR
City
STOCKTON
Zip
95206
APN
16336003
CURRENT_STATUS
01
SITE_LOCATION
1477 TILLIE LEWIS DR
QC Status
Approved
Scanner
FRuiz
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
50
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Section 5 of the standard addresses the criteria, including AST type,size,type of installation, corrosion <br /> rate, and previous inspection history, if any,that should be used to develop a schedule of inspections for each <br /> AST. <br /> A Table of Inspection Schedules (Table 5.5) places tanks into one of three categories and establishes <br /> different requirements regarding the type and frequency of periodic inspection by tank owner/operators as well <br /> as formal external and internal inspections by a certified inspector.The factors used for categorizing tanks <br /> include: <br /> • Tank size, <br /> • Whether the tank is in contact with the ground, <br /> • The presence or absence of secondary containment or spill control, and <br /> • The presence or absence of a continuous release detection method (CRDM). <br /> Section 6 of the standard provides guidelines for the periodic inspections conducted by the owner or <br /> his/her designee.The owner's inspector is to complete an AST Record for each AST or tank site, as well as a <br /> Monthly Inspection Checklist and an Annual Inspection Checklist. Monthly inspections should monitor water <br /> accumulation to prevent Microbial Influenced Corrosion (MIC), and action should be taken if MIC is found. <br /> Additional requirements for field-erected tanks are in Appendix B of STI SP001. <br /> Section 7 of the standard contains the minimum inspection requirements for formal external <br /> inspections,which are to be performed by a certified inspector. Inspections should cover the AST foundations, <br /> supports, secondary containment, drain valves, ancillary equipment, piping,vents,gauges, grounding system (if <br /> any), stairways, and coatings on the AST. Original shell thickness should be determined using one of several <br /> suggested methods. Ultrasonic Thickness Testing (UTT) readings are to be taken at different locations of the AST <br /> depending upon whether the AST is horizontal,vertical, rectangular, and/or insulated.The final report should <br /> include field data, measurements, pictures, drawings,tables, and an inspection summary, and should specify the <br /> next scheduled inspection. <br /> Section 8 of the standard details the minimum inspection requirements for formal internal inspections, <br /> which are to be performed by a certified inspector.A formal internal inspection includes the requirements of an <br /> external inspection with some additional requirements for specific situations that are outlined in the standard. <br /> Double-wall tanks and secondary containment tanks may be inspected by checking the interstice for liquid or by <br /> other equivalent methods. For elevated ASTs where all external surfaces are accessible,the internal inspection <br /> may be conducted by examining the tank exterior using such methods as Ultrasonic Thickness Scans(UTS). For <br /> all other situations, entry into the interior of the AST is necessary. Internal inspection guidelines are detailed <br /> separately for horizontal ASTs and for vertical and rectangular ASTs in Sections 8.2 and 8.3 of the standard, <br /> respectively.Additional requirements for field-erected tanks are in Appendix B.The final report should contain <br /> elements similar to reports prepared for external inspections. <br /> SPCC GUIDANCE FOR REGIONAL INSPECTORS 7-65 <br /> December 16, 2013 <br />
The URL can be used to link to this page
Your browser does not support the video tag.