28 January 2019 AdvancedGeo <br /> AGE Project No. 05-1339 Environmental <br /> Page 5 of 24 <br /> the location and content of ASTs, transfer stations and connecting piping, where <br /> appropriate. <br /> 3.5.3. Distance to Navigable Waters and Adjoining Shorelines and Flow Paths <br /> The Facility is located on relatively level terrain. Drainage generally flows towards the <br /> center of the Facility. The nearest navigable water or adjoining shoreline is French Camp <br /> Slough, located approximately one-mile northwest of the facility. Spill trajectories offsite <br /> would travel through overflow of the onsite facility oilfwater separator (OWS). The spill <br /> would be diverted to the subsurface stormwater conduit to a water basin north of Sperry <br /> Road, 4,000 feet northwest of the facility. An east to west traversing and unnamed <br /> tributary is located at the far north end of the water basin. The tributary does not flow <br /> frequently but would most likely discharge into the French Camp Slough, one mile from <br /> the basin in-flow pipe located on the north corner of the intersection of Sperry Road and <br /> Performance Road. However, a facility spill with potential for offsite discharge is highly <br /> unlikely due to facility contingencies as discussed in Section 4.0., including: <br /> • Secondary containment provided for all fixed ASTs. <br /> • Surface containment provided for tanker dischargers utilizing facility spill response <br /> procedures. <br /> • Safe Drains® installed on six (6) drain inlets located throughout the main area of <br /> the facility. <br /> • Oil Water Separator at the central west area of the Facility. <br /> 3.5.4. Discharge History <br /> The Facility has not had any discharges since the last revision of this SPCCP. Table 4 <br /> summarizes the Facility's discharge history. <br /> 3.5.5. Material Stored at this Facility — 112.7(a)(3)(i) <br /> Oil storage at the Facility consists of twelve (12) aboveground storage tanks (ASTs), <br /> various 275-gallon rectangular polyethylene totes and various 55-gallon drums containing <br /> petroleum products. Facility containers are summarized below and included in Table 3. <br /> The approximate locations where oil is stored are illustrated in Figure 2. <br /> Tank Type Capacity Contents Location Active <br /> ID Gallons <br /> 1 VerticalSteel AST 10,000 HT/4 Fluid 30 Yes <br /> UL142 AST Tank Farm — <br /> 2 VerticalSteel AST 10,000 SAE 15W-40 South of Warehouse Yes <br /> (U L142 Building 1 <br /> 3 VerticalSteel AST 10,000 SAE 15W-40 Yes <br /> (U L142 <br />