Laserfiche WebLink
UNDERGROUNDSTORAGEIANK <br />MONITORING PLAN - PAGE 2 <br />.. . . -DIS... ... ... T-0-ZRIN, <br />MONITORING OF AREAS BENEATH DISPENSER(S) IS PERFORMED USING THE FOLLOWING METHOD(S) (Check all that apply) M50 <br />I CONTINUOUS ELECTRONIC MONITORING OF UNDER DISPENSER CONTAINMENT (UDC) <br />M52 <br />PANEL MANUFACTURER: Veeder Root M" MODEL #: ILS 350 <br />M54 <br />LEAK SENSOR MANUFACTURER: Veeder Root m53 MODEL #(S): 794380-323 <br />WILL DETECTION OF A LEAK INTO THE UDC TRIGGER AUDIBLE AND VISUAL ALARMS? 0 a. YES [Ib NO M55 <br />WILL A UDC LEAK ALARM TRIGGER AUTOMATIC PUNT SHUTDOWN? Z a. YES El b NO M"' <br />WILL FAILURE/DISCONNECTION OF UDC MONITORING SYSTEM TRIGGER AUTOMATIC PUMP SHUTDOWN? 0 a YES El b NO M57 <br />❑ 2 MECHANICAL ASSEMBLY (e g: FI -CAT AND CHAIN ASSEMBLY) IN UDC TRIPS SHEAR VALVE IN CASE OF LEAK <br />ASSEMBLY MANUFACTURER: M58 MODEL #(S). M59 <br />El 3 VISUAL MONITORING DONE: [I a DAILY El b WEEKLY (Requires agencypproval) M60 <br />[1 4 NO DISPENSERS <br />El 99. OTHER (Specify) <br />VII.:.ENHANCED LEAK DETECTTON <br />El I WE HAVE BEEN NOTIFIED BY THE STATE WATER RESOURCES CONTROL BOARD THAT WE MUST IMPLEMENT ENHANCED LEAK M70 <br />DETECTION (FLD) FOR IH5 UST(S) COVERED BY THIS PLAN PER 23 CCR §2644 1, ELD IS PERFORMED EVERY 36 MONTHS AS REQUIRED <br />V11L -T-1(ARq1N'G <br />REFERENCE DOCUMENTS MAINTAINED AT FACILITY (Check all that apply) M80 <br />1 0 THIS UNDERGROUND STORAGE TANK MONITORING PLAN (Required) <br />2 0 OPERATING MANUALS FOR ELECTRONIC MONITORING EQUIPMENT (Required)* <br />3 0 THE FACILITY'S BEST MANAGEMENT PRACTICES (Required as of MWkDDiYY) <br />4 n CALIFORNIA UNDERGROUND STORAGE TANK REGULATIONS <br />5 0 CALIFORNIA UNDERGROUND STORAGE TANK LAW <br />6 F-1 STATE WATER RESOURCES CONTROL BOARD (SWRCB) PUBLICATION: "HANDBOOK FOR TANK OWNERS MANUAL AND <br />STATIS rICAL. INVENTORY RECONCILIATION" <br />7. D SWRCB PUBLICATION: "WEEKLY MANUAL TANK GAUGING FOR SMALL UNDERGROUND STORAGE TANKS' <br />99 El OTHER (Specify): yat <br />Personnel with LIST monitoring responsibilities are familiar with all of the above documents relevant to their job duties and can access those documents when needed <br />By I/1/2005, this facility will have a "Designated UST Operatof who has passed the operator exam administered by the international Code Council (ICC) By July 1, <br />2005, and annually thereafter, the 'Designated UST Operatoet will train facility employees in the proper operation and maintenance of the LIST systems This training <br />will include, but is not limited to, the following: <br />> Operation of the UST systems in a manner consistent with the facility s best management practices <br />> The facility employee s role with regard to the leak detection equipment <br />> The facility employee's role with regard to spills and overfills <br />> Whom to contact for emergencies and leak detection alarms <br />For facility employees hired on or after July 1, 2005, the initial training will be conducted within 30 days of the date of hire. <br />JX. - COMMENTS/ADDITIONAL INFORMATION <br />Please use this section to include any additional UST system monitoring -related information (c g additional information required by your local agency): Mss <br />*Monitoring systems manual maintained by contracted, licensed pump and tank technicians. <br />Best Management Practices are maintained in the H.S.S.E.. Retail Facility Programs Manual (Green Binder). <br />*Tank Overfill Protection Type: OVER F:1LLN#AA and Ball Float, alarm visual and audible at tank rill point(s) and <br />operates alarm trigger- at 90%. <br />X, PERSONNEL USPOWB11ITIES. <br />THE FACILITY OPERATOR DESIGNATED IN SECTION XI BELOW IS RESPONSIBLE FOR PEFORMINU MONITORING BP WEST COAST PRODUCTS <br />LLC IS RESPONSIBLE FOR MAINTAINING AND TESTING ALL MONITORING EQUIPMENT. <br />-6VVNERJOPERATQI2 SIGNATURE <br />CERTIFICATION: I certify that the information provided herein is true and accurate to the best of my knowledge.. <br />M91 <br />OWNERIOPE R SIGNATUP REPRESENTING DATE: <br />El Owner M9D <br />�// I �0 -� <br />Z16' 0q- Z Operator <br />OWNER/OPE�ATOR NANNIt (print): <br />OWNER/OPERATOR TITLE: <br />KEVIN VO <br />DEALER <br />(Agency Use only) Ibis plan has been reviewed and: rp Approved El Approved With Conditions ❑ Disapproved <br />I ocal Agency Signature: Date: �110 01 <br />Comments/Special Conditions: <br />Arco # 02186 Selshire Environmental Services Page 2 of 5 <br />