My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2010 - 2012
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CALIFORNIA
>
3212
>
2300 - Underground Storage Tank Program
>
PR0231035
>
COMPLIANCE INFO 2010 - 2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/3/2022 4:35:27 PM
Creation date
3/28/2019 8:40:14 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010 - 2012
RECORD_ID
PR0231035
PE
2361
FACILITY_ID
FA0006773
FACILITY_NAME
ARCO 02186
STREET_NUMBER
3212
Direction
N
STREET_NAME
CALIFORNIA
STREET_TYPE
ST
City
STOCKTON
Zip
95204
APN
12532001
CURRENT_STATUS
01
SITE_LOCATION
3212 N CALIFORNIA ST
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
296
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
®6ETTLER-RYAN INC. GR Job # 20-582062.1 <br /> Appendix VI <br /> MONITORING SYSTEM CERTIFICATION <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of <br /> Regulations <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared for <br /> each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system <br /> owner/operator.The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General Information <br /> Facility Name: Arco 2186 Bldg.No.: <br /> Site Address: 3212 N. California city Stockton zip: 95204 <br /> Facility Contact Person: Contact Phone No.: <br /> Make/Model of Monitoring System: TLS 350 Date of Testing/Servicing: 10/16/2012 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to Indicate specific equipment Inspected/serviced: <br /> Tank ID: 1-Reg Tank ID: 2-Reg <br /> © In-Tank Gauging Probe. Model: MAG 1 © In-Tank Gauging Probe. Model: MAG 1 <br /> © Annular Space or Vault Sensor. Model: 794390.409 © Annular Space or Vault Sensor. Model: 794390-409 <br /> © Piping Sump/Trench Sensor(s). Model: 794380-323 CiJ Piping Sump/Trench Senscr(s). Model: 794380-323 <br /> Q Fill Sump Sensor(s). Model: 794380-323 © Fill Sump Sensor(s). Model: 794380-323 <br /> ❑ Mechanical Line Leak Detector. Model: ❑ Mechanical Line Leak Detector. Model: <br /> © Electronic Line Leak Detector Model: 8484 Cil Electronic Line Leak Detector Model: 8484 <br /> ❑ Tank Overfill/High-Level Sensor. Model: ❑ Tank Overfill/High-Level Sensor. Model: <br /> ❑ Other(specify equipment and model in Section E on Page 2). ❑ Other(specify equipment and model in Section E on Page 2). <br /> Tank ID: 3-Premium Tank ID: <br /> © In-Tank Gauging Probe. Model: MAG 1 ❑ In-Tank Gauging Probe. Model: <br /> ❑ Annular Space or Vault Sensor. Model: ❑ Annular Space or Vault Sensor. Model: <br /> © Piping Sump/Trench Sensor(s). Model: 794380-323 ❑ Piping Sump/Trench Sensor(s). Model: <br /> Cia Fill Sump Sensor(s). Model: 794380.323 ❑ Fill Sump Sensor(s). Model: <br /> ❑ Mechanical Line Leak Detector. Model ❑ Mechanical Line Leak Detector. Model: <br /> Cil Electronic Line Leak Detector Model: 8484 ❑ Electronic Line Leak Detector Model: <br /> ❑ Tank Overfill/High-Level Sensor. Model: ❑ Tank Overfill/High-Level Sensor. Model: <br /> ❑ Other(specify equipment a and model in Section E on Page 2). ❑ Other(specify ui ent type and model in Section E on Page 2). <br /> Dispenser ID: Dispenser 1&2 Dlspenser ID: Dispenser 3&4 <br /> Cil Dispenser Containment Sensor(s). Model: 794380-323 D Dispenser Containment Sensor(s). Model: 794390-323 <br /> IR Shear Valve(s). a Shear Valve(s). <br /> ❑ Dispenser Containment Float(s) and Chain(s). ❑ Dispenser Containment Floa s and Chain(s). <br /> Dispenser ID: Dispenser 5&6 Dispenser ID: Dispenser 7&8 <br /> 9 Dispenser Containment Sensor(s). Model: 794380-323 10 Dispenser Containment Sensor(s). Model: 794390-323 <br /> Cid Shear Vatve(s). © Shear Valve(s). <br /> ❑ Dispenser Containment Floats and Chain(s). ❑ Dispenser Containment Floa s and Chain(s). <br /> Dispenser ID: DispenserlD: <br /> ❑ Dispenser Containment Sensor(s). Model: ❑ Dispenser Containment Sensor(s). Model: <br /> ❑ Shear Valve(s). ❑ Shear Valve(s). <br /> ❑ Dispenser Containment Floats and Chain(s). ❑ Dispenser Containment Floats and Chain(s). <br /> If the facility contains more tanks or dispensers,copy this form.Include information for every tank and dispenser at the facility. <br /> C. Certtfication - I certify that the equipment Identified in this document was inspected/serviced In accordance with the manufacturers' <br /> guidelines. Attached to this Certification Is Information (e.g. manufacturers' checklists) necessary to verify that this Information is correct <br /> and a Plot Plan showing the layout of monitoring equipment For any equipment capable of generating such reports, I have also attached a <br /> copy of the report;(check all that apply): CO System set-up p Alarm history report <br /> Technician Name(print): Wes Morrison Signature: Wes Morrison <br /> Certification No.: B38044 License.No.: 220793 <br /> Testing Company Name: Gettler-Ryan Inc. Phone No.: 925-551-7555 <br /> Testing Company Address: 6747 Sierra Court Suite J, Dublin, Ca. 94568 Date of Testing/Servicing: 10/16/2012 <br /> Monitoring System Certification Page 1 of 4 12/07 <br /> 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.