Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2017
RECORD_ID
PR0231035
PE
2361
FACILITY_ID
FA0006773
FACILITY_NAME
ARCO 02186
STREET_NUMBER
3212
Direction
N
STREET_NAME
CALIFORNIA
STREET_TYPE
ST
City
STOCKTON
Zip
95204
APN
12532001
CURRENT_STATUS
01
SITE_LOCATION
3212 N CALIFORNIA ST
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
430
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
t7Err1ER-11YAN W. GR Job# 17200007 <br /> D. Results of Testing/Servicing k "" <br /> RECEIV' ti. 0 <br /> Software Version Installed: 334.00 JAN <br /> HSV hl 3 I 20 <br /> 17 <br /> Complete the following checklist: <br /> esr <br /> s the audible alarm operational? <br /> Yess the visual alarm operational? <br /> YesNo, ere all sensors visually inspected,functionally tested,and confirmed operational? — <br /> [� Yesere all sensors installed at lowest point of secondary containment and positioned so that other equipment will not interfere with their <br /> Proper operation? <br /> Yes alarms are relayed to a remote monitoring station,is all communication equipment(e.g.modem)operational? <br /> [yYesor pressurized piping systems,does the turbine automatically shut down if the piping secondary containment monitoring system <br /> etects a leak,fails to operate,or is electrically disconnected?If yes:which sensors initiate positive shut-down?(Check a/1 that apply) <br /> Sump/Trench Sensor: Dispenser Containment Sensor.Did you confirm positive shut-down due to leaks and sensor <br /> ilure/disconnection? Yes, ❑ No. <br /> Yes ❑ No' For tank systems that utilize the monitoring system as the primary tank overt 11 warning device tLe,no mechanical overfill prevention <br /> ❑ N/A valve is installed),is the overfill warning alarm visible and audible at the tank fill point(s)and operating properly?If so,at what percent <br /> of tank capacity does the alarm trigger? 90 <br /> Yes ❑ No Was any monitoring equipment replaced?If yes,identify specific sensors,probes,or other equipment replaced and list the <br /> manufacturer name and model for all replacement arts in Section E,below. <br /> ❑ Yes No Was liquid found inside any secondary containment systems designed as dry systems?(Check all that apply) []Product, ❑Water If <br /> yes,describe causes in Section E,below. <br /> Yes ❑ No' Was monitoring system set-up reviewed to insure proper settings?Attach set-up reports,if applicable. <br /> Yes ❑ No' Is all monitoring equipment operational per manufacture's specifications? <br /> In Section E below,describe how and when these deficiencies were or will be corrected. <br /> E. Comments: <br /> Replaced (2) 208 sensors in 87-1 STP and 91 STP sumps. <br /> Monitoring System Certification Page 2 of 4 12/07 <br /> 2 <br />