Laserfiche WebLink
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax; (209)468-3433 Web:www.sjaov.orcI/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> RYDER TRUCK RENTAL#1071 3633 DUCK CREEK DR STOCKTON January 16 2019 <br /> Other Violations <br /> 2010 1 See below Unlisted General violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 104 CCR 2711 UST operating permit application for facility and tank information not submitted or current. <br /> UST Tank Information forms are not current in CERS. <br /> -The new oil tank form states the tank uses a gravity piping system. According to the monitoring plan, the new oil <br /> tank uses a safe suction system. <br /> -The tank forms for all four tanks list the vent and vapor recovery pipes as having steel primary piping and fiberglass <br /> secondary piping. Fiberglass primary piping was observed in the sumps. <br /> Any change of information must be updated in CERS within 30 days of the changes. Immediately log into CERS, <br /> update the required information, and submit for review by the EHD. <br /> This is a repeat violation, Class II. <br /> 105 CCR 2632(d)(1), 2634(d) Failed to have an approved UST monitoring plan. <br /> The monitoring plans are not current and/or not approved by the EHD. <br /> -The monitoring plan for the new oil tank incorrectly states the secondary containment is liquid-filled. <br /> The monitoring plan must be uploaded to the California Environmental Reporting System (CERS). Immediately log <br /> into CERS, make the necessary changes, and submit for review by the EHD. <br /> This is a repeat violation, Class II. <br /> 110 CCR 2637(e), 2637(f) Failed to submit"Secondary Containment Testing Report Form"within 30 days after the test. <br /> Secondary containment testing was performed on 1/5/18 and a test report was submitted on 3/1/18, one month late. <br /> A copy of the test report must be submitted within 30 days of the tests. Take all necessary precautions to ensure <br /> testing and submittal of test reports are performed in a timely manner. <br /> This is a minor violation. <br /> 121 CCR 2712(f) Failed to submit a written response within 30 days of receiving an inspection report. <br /> An inspection was last done on 1/4/18 and an inspection report was issued identifying information to be submitted to <br /> bring this site into compliance. This information was required to be submitted by 2/3/18. This information was <br /> received late, on 5/7/18 for most violations and 5/11/18 for the spill container violation. An operator that receives an <br /> inspection report shall have 30 days to submit a written response that includes a statement documenting corrective <br /> actions taken or proposing corrective actions which will be taken. Ensure that a written response documenting <br /> corrective actions taken or proposed is submitted within 30 days of receiving an inspection report. <br /> This is a repeat violation, Class II. <br /> FA0003758 PR0232461 SCO01 01/16/2019 <br /> EHD 23-01 Rev.09/22/16 Page 4 Of 8 Underground Storage Tank Program OIR <br />