My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2009 - 2013
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CAPITOL
>
6421
>
2300 - Underground Storage Tank Program
>
PR0231706
>
COMPLIANCE INFO 2009 - 2013
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/11/2019 11:57:34 AM
Creation date
4/10/2019 3:28:15 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009 - 2013
RECORD_ID
PR0231706
PE
2361
FACILITY_ID
FA0000485
FACILITY_NAME
FLAG CITY CHEVRON
STREET_NUMBER
6421
STREET_NAME
CAPITOL
STREET_TYPE
AVE
City
LODI
Zip
95242
APN
05532024
CURRENT_STATUS
01
SITE_LOCATION
6421 CAPITOL AVE
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
332
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN.JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sagov.org/ehd/unitiii.html <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br /> CONTINUED <br /> Facility address: Inspection Date: <br /> 6421 Capitol Ave Lodi CA July 26, 2011 <br /> VIOLATIONS V R <br /> # Code Section HSC=CA Health&Safe Code;CCR=CA Code of Re ulations;V=Violation; RV=Re eat Violation V <br /> Designated operator monthly inspection:(c)(1)alarms not documented; (c)(2-4)spill containers, <br /> 23c CCR 2715(c),(e) UDCs,and sumps(if necessary)not inspected; (c)(5)required test dates not checked or noted;(c)(6) <br /> employee training not verified; (e)monthly inspection reports not maintained on site for at least 12 <br /> months <br /> 23d CCR 2715(f) Designated operator employee training: (1)not performed; (2)not current for at least one employee <br /> on site; 3 log not kept <br /> Monitoring equipment certification:(a)not performed annually; (d)test report not submitted within 30 <br /> 24 CCR 2638 days; (e)test notification not provided to the EHD at least 48 hours prior to conducting an installation, <br /> repair, replacement,calibration,or certification; (f)performed, and failed to affix a tag/sticker on each <br /> monitoring equipment com onent that was certified, repaired,or replaced <br /> 25 HSC 25291 Annual line leak detector test not performed (Mi) <br /> 26 HSC 25284.2 Annuals ill containment testing not performed <br /> 27 CCR 2636 4 Annual line tightness test not performed if positive shutdown or fail safe not present (MI) <br /> 28 CCR 2660(k) Repair for tank or piping not tested for tightness after completion of the repair pursuant to permit (M2) <br /> conditions <br /> 29 CCR 2643 a Biennial ti htness test of ravit piping not performed re-Janus 1, 1984 (Mi)_ <br /> 30 CCR 2643(d) Triennial line test for conventional suction piping not performed re-Janus 1, 1984 (Mi) <br /> 31 HSC 25292.5 ELD testing not performed on a system located within 1000'of public well,or failures not repaired and <br /> retested <br /> 32 CCR 2661 Permit to repair UST system not obtained <br /> 33 HSC 25286(a) Operational permit not amended when UST storage and/or monitoring s stem changed <br /> 34 HSC 25298(b) Permit to temporarily close UST system not obtained <br /> 35 HSC 25298(c) Permit to close UST system not obtained <br /> 36 HSC 25299(9(2) Tampering with or disabling leak detection devices or alarms <br /> 37 HSC 25298(a) llleqally abandoned UST system <br /> 38 HSC 25281.5(b)(2) Unburied fuel piping at marinas not visual) inspected at least daily or to not kept <br /> 39 CCR 263 1.1 a UST system is not compatible with the substance stored <br /> Emergency enerator systems <br /> 40 1 CCR 2636(0(6) Emergency enerator monitoring system not checked daily or log not kept if no leak detector (Mi) <br /> 41 1 HSC 25281.5(b)(3) I Unburied fuel piping not visually inspected at least monthly or log not kept (Mi) <br /> AB 1702(2003-2004) HSC 25290.2(installed between 07/01/03 and 06/30/04) <br /> VPH Systems HSC 25290.1 installed on or after 07/01/04 <br /> Compatibility and permeability requirements: (a)UST system is not compatible with the substance <br /> 42 CCR 2631.1 stored;(b)results of the compatibility and permeability testing requirements listed in subsections CCR <br /> 2631 b and d for a UST system installed after July 1,2004,were not submitted <br /> 43 HSC 25290.1(c)(1) Primary containment not liquid or vapor tight <br /> HSC 25290.2(c)(1) <br /> 44 HSC 25290.1(c)(2) Secondary containment not liquid or vapor tight <br /> HSC 25290.2 c 2 <br /> 45 HSC 25290.1(c)(3) Secondary containment not constructed to prevent water intrusion <br /> HSC 25290.2 c 3 <br /> 46 HSC 25290.1(d) Monitoring system not maintained to detect water intrusion into the secondary containment,or (Mi) <br /> HSC 25290.2(d) the entry of liquid or vapor from the primary containment into the secondary containment <br /> 47 HSC 25290.1(e) Interstitial liquid measurement method, constant vacuum, or constant pressure in the interstitial (Mi) <br /> space of the UST system not maintained <br /> HSC 25290.10) UST system not tested by one of the following methods prior to use: (1) Enhanced leak detection;(2) <br /> 48 HSC 25290.2(i) inert gas pressure test approved by SWRCB; (3)test method deemed equivalent to(1)or(2)by the <br /> SWRCB <br /> Other violations <br /> 999 Other: See attached"Continuation—Official Inspection Report"for violation(s)not listed above. <br /> EHD' spector: Phone: Septic system: UIC <br /> t/ `�J'/Vh//l/ i!Serves>_20 people/day <br /> Received Tale: I I Receives other than sanitary waste <br /> Other disposal methods: <br /> I Dry wells/French Drains <br /> EHD 23-02-002 R 07/12/11 Page 2 UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.