My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2014 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CAPITOL
>
6421
>
2300 - Underground Storage Tank Program
>
PR0231706
>
COMPLIANCE INFO_2014 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/11/2019 2:30:29 PM
Creation date
4/10/2019 4:46:46 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2014 - 2018
RECORD_ID
PR0231706
PE
2361
FACILITY_ID
FA0000485
FACILITY_NAME
FLAG CITY CHEVRON
STREET_NUMBER
6421
STREET_NAME
CAPITOL
STREET_TYPE
AVE
City
LODI
Zip
95242
APN
05532024
CURRENT_STATUS
01
SITE_LOCATION
6421 CAPITOL AVE
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
374
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
VAPOR VALVE THERMOMETER TEST <br /> 7.3.2 <br /> Vapor polisher ambient temperature 76.44 <br /> Vapor polisher outlet temperature 67.40 <br /> Difference between ambient and outlet temperatures 9.04 <br /> Is the difference less than 10°F? If not,proceed to section 9.2.1 Yes <br /> 9.2.2 <br /> Vapor polisher ambient temperature <br /> Vapor polisher outlet temperature <br /> Difference between ambient and outlet temperatures <br /> Is the difference less than 10°F?If not,proceed to section 9.2.4 <br /> 9.2.4&9.2.5 <br /> Vapor polisher ambient temperature <br /> Vapor polisher outlet temperature <br /> Calibrated thermometer ambient temperatures <br /> Difference between outlet temperature and the calibrated thermometer <br /> Is the difference less than 10°F?If not,the outlet thermometer does not meet specifications <br /> Difference between ambient temperature and the calibrated thermometer <br /> Is the difference less than 10°F?if not,the ambient thermometer does not meet specifications <br /> UST THERMOMETER TEST <br /> UST 41 7.3.3 <br /> T5 temperature 81.185 <br /> T4 temperature 80.788 <br /> Difference between T5 and T4 temperatures 0.397 <br /> Is the difference less than 10°F? If not,proceed to section 9.1 Yes <br /> 9.1 <br /> T5 temperature <br /> Calibrated thermometer ambient temperature <br /> Difference between T5 and calibrated thermometer <br /> Is the difference less than 10°F?If not,the T5 thermometer does not meet specifications <br /> UST 42 7.3.3 <br /> T5 temperature 81.664 <br /> T4 temperature 81.736 <br /> Difference between T5 and T4 temperatures -0.072 <br /> Is the difference less than lo°F? If not,proceed to section 9.1 Yes <br /> 9.1 <br /> T5 temperature <br /> Calibrated thermometer ambient temperature <br /> Difference between T5 and calibrated thermometer <br /> Is the difference less than 10°F?If not,the T5 thermometer does not meet specifications <br /> I declare, under penalty of perjury under the laws of the state of California that based on information and belief formed <br /> after reasonable inquiry, the statements and information provided in this document are true, accurate, and complete. <br /> Signature of Technician: Date: 9/26/18 <br /> Ver. LI -01.20.09 <br />
The URL can be used to link to this page
Your browser does not support the video tag.