Laserfiche WebLink
SAN J O � � I `II411, Environmental Health Department <br /> C0IJNT`r' <br /> Large Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> JAAS AUTO SERVICE 414 W CHARTER WAY, STOCKTON November 30, 2018 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 120 HSC 25160.2(b)(4)Consolidated manifest receipts failed to contain complete information. <br /> The following consolidated manifest receipts were observed incomplete: <br /> -Used oil invoice 490(8/2/2018)from Crystal Blue Environmental was observed without a generator's signature. <br /> -Used oil invoice 454(6/17/2018)from Crystal Blue Environmental was observed without a generator's signature. <br /> All copies of each receipt shall contain all of the following information: <br /> -The name, address, identification number, contact person, and telephone number of the generator, and the <br /> signature of the generator or the generator's representative; <br /> -The date of the shipment; <br /> -The manifest number; <br /> -The volume or quantity of each waste stream received, its California and RCRA waste codes,the waste stream <br /> type listed in subdivision (c), and its proper shipping description, including the hazardous class and United <br /> Nations/North America(UN/NA)identification number, if applicable; <br /> -The name, address, and identification number of the authorized facility to which the hazardous waste will be <br /> transported; <br /> -The transporter's name, address, and identification number; <br /> -The driver's signature; <br /> -A statement, signed by the generator, certifying that the generator has established a program to reduce the <br /> volume or quantity and toxicity of the hazardous waste to the degree, as determined by the generator,to be <br /> economically practicable. <br /> Ensure that all future receipts for hazardous waste shipments using a consolidated manifesting procedure contain <br /> all required information. <br /> This is a Class II violation. <br /> 121 CCR 66266.81(a)(4)(B)Failed to retain copy of manifest or bill of lading for spent lead acid batteries for 3 years. <br /> Bills of lading or manifests for the management of lead acid batteries for the last three years were not found on site. <br /> A copy of each bill of lading must be kept on site for at least three years. Immediately locate a copy of all bills of <br /> lading or manifests for lead acid batteries for the last three years, maintain them on site, and submit copies to the <br /> EHD. <br /> This is a repeat violation, Class II. <br /> 123 HSC 25185(c)(3) Failed to submit a written response within 30 days of receiving an inspection report. <br /> An inspection was last done on 8/2/2016 and an inspection report was issued identifying information to be submitted <br /> to bring this site into compliance. This information was required to be submitted by 9/1/2016. This information has <br /> not been received resulting in a non-compliant status for this facility. An operator that receives an inspection report <br /> shall have 30 days to submit a written response that includes a statement documenting corrective actions taken or <br /> proposing corrective actions which will be taken. Ensure that a written response documenting corrective actions <br /> taken or proposed is submitted within 30 days of receiving an inspection report. <br /> This is a repeat violation, Class II. <br /> FA0010746 PR0514402 SCO01 11/30/2018 <br /> EHD 22-02 Rev.8/22/2019 Page 7 of 11 Large Quantity Hazardous Waste Generator OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />