Page 2 of 2 <br /> To: Aris Cacapit [EH] <br /> Subject: certifications: Able Maintenance, Inc. RE. Tesoro/USA stations in Lockeford & Lodi <br /> Aris, <br /> As requested, I have attached the ICC and manufacturer certifications (as applicable)for our techs. As you <br /> are aware, our crew will incorporate multiple specialists for different phases of the project. The breakdown <br /> is shown below. <br /> Mark Tillotson (Able Maintenance)will be responsible for Veeder-Root, Gilbarco& Flex-ing equipment <br /> installation. <br /> ICC#5252035-U1 exp.8/4/2011, Veeder-Root#B36500 exp. 8/1/2012 (includes Gilbarco), Flex-ing <br /> exp.5/16/2012 <br /> James Moore(Able Maintenance)will be responsible for OPW, Phil-Tite/Healy/INCON equipment(as <br /> applicable). <br /> ICC#5254517-UT exp.8/7/2011, OPW#P05480 exp.1/27/2012, Franklin Fueling#4951493760 <br /> exp.1/28/2011 (includes Phil-Tite/Healy/INCON) <br /> The complete OPW installer certification list is available at <br /> http://A .opwglobal.com/Libraries/EVR Contractors/EVR certified technicians.sflb.ashx <br /> Chris Barron (Service Station Systems)will be responsible for re-programming of the Veeder-Root for <br /> diesel monitoring. <br /> ICC#5284954 exp.7/7/2012, Veeder-Root#B33164 (this is a Level 4 Certification)exp. 3/2/2012. <br /> The Bravo Gold certification is a company wide certification issued to Able Maintenance (all employees are <br /> included). The owner, Rod Brownlee, is listed as the contact. You may view the current Bravo Gold <br /> certification list at the following web address: <http://www.sbravo.com/certlist.htm> <br /> The Husky Corporation does not maintain a certification program. <br /> I double-checked the requirements regarding installation of a Husky 5885 vent cap and 1A dispenser <br /> nozzle and both require an ICC UST installer certification only. <br /> Mark Tillotson will be responsible for installation of the Husky 5885 vent and 1A nozzle. <br /> Please let me know if you had a different certification in mind? <br /> I have also attached the adapter/containment frame(aka dispenser shield) brochures for your reference. A <br /> SAMPLE copy of the Western Fiberglass order form (this is NOT the actual order for this project) is also <br /> attached for your reference. I do not have a Bravo order form on file. At this time, we intend to use a <br /> Bravo dispenser shield. <br /> Please let me know if you have any other questions. <br /> Eric Janzen <br /> Code Compliance Officer <br /> Able Maintenance, Inc. <br /> ph: (707) 293-2986 <br /> fax: (707)545-5515 <br /> 11/30/2010 <br />