My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2010 - 2012
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
2448
>
2300 - Underground Storage Tank Program
>
PR0231948
>
COMPLIANCE INFO 2010 - 2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/19/2022 9:57:59 AM
Creation date
4/29/2019 11:40:24 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010 - 2012
RECORD_ID
PR0231948
PE
2361
FACILITY_ID
FA0003855
FACILITY_NAME
TESORO (SHELL) 68153
STREET_NUMBER
2448
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
05814001
CURRENT_STATUS
01
SITE_LOCATION
2448 W KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
363
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FEB-25-2011 15:36 Service Station Systems 408 938 8888 P.04 <br /> 4. TANK ANNULAR TESTING <br /> Test Method Developed By: ❑Tank Manufacturer ® Industry Standard ❑ Professional Engineer <br /> El Other(Specify) <br /> Test Method Used; ❑Pressure ®Vacuum 0 Hydrostatic <br /> 0 Other(Specify) <br /> Test Equipment Used: Test plugs, venturi puntp and gauges Equipment Resolution: 0.5% of span <br /> I <br /> Tank#87 Tank#89 Tank#91 <br /> Is Tank Exempt From Testing? ❑ Yes ®No ❑ Yes ®No i El Yes 21 No <br /> Tank Capacity: 12k 12k 12k <br /> Tank Material: Fiberglass Fiberglass I Fiberglass <br /> Tank Manufacturer: Owens Corning Owens Corning Owens Corning <br /> Product Stored: Gasoline Gasoline Gasoline <br /> Wait time between applying j <br /> pressure/vacuum/water and 10 min 10 min 10 min <br /> starting test: <br /> Test Start Time: 7:30 am 7:56 am 9:15 am <br /> Initial Reading(Rt): 7"hg 7"hg 7"hg <br /> 'fest End Thne: 8:30 am 8:56 am 10:15 am <br /> Final Reading(RF): 7" hg 7"hg 7"ha <br /> 'fest Duration: 1 hour I hour I hour <br /> Change in Reading(Rr•R,): Nona Nonc None <br /> Pass/Fail Threshold or Criteria: No Detectable Loss No Detectable Loss No Detectable Loss ._. <br /> Test Result; © Pass 0 Fail ® Pass C Fail ® Pass 0 Fail <br /> Was sensor removed for testing? E]Yes ® No [I NA ©Yes® No El NA ©Yes® No ❑NA <br /> Was sensor properly replaced and dyes [] No NA [JYes L:] No NA ❑Yes ❑No ®NA <br /> verified functional after testing? <br /> Comments— (include information on repairs made prior to testing, aJid recommended follow-up for failed tests) <br /> "Sensor functionality was not confirtned.This procedure is not part of the Secondary Containment testing scope of work", <br /> ` Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br /> containment,such as systems that are hydrostatically monitored or under constant vacuum, are exempt from periodic containment <br /> testing, {California Code of Regulations, Title 23, Section 2637(a)(6)' <br />