COMPLIANCE INFO 2010 - 2012
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
2448
>
2300 - Underground Storage Tank Program
>
PR0231948
>
COMPLIANCE INFO 2010 - 2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/19/2022 9:57:59 AM
Creation date
4/29/2019 11:40:24 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010 - 2012
RECORD_ID
PR0231948
PE
2361
FACILITY_ID
FA0003855
FACILITY_NAME
TESORO (SHELL) 68153
STREET_NUMBER
2448
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
05814001
CURRENT_STATUS
01
SITE_LOCATION
2448 W KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
363
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4. TANK ANNULAR TESTING <br /> Test Method Developed By: ❑Tank Manufacturer ®Industry Standard ❑ Professional Engineer <br /> ❑ Other(Specify) <br /> Test Method Used: p Pressure ®Vacuum []Hydrostatic <br /> ❑Other(.Sped) <br /> Test Equipment Used: Test plugs,venturi pump and gauges Equipment Resolution: 0.5%of span <br /> 7Ta:nk <br /> Tank#87 Tank#89 Tank 0 91 <br /> xempt From Testing?' ❑ Yes 22 No ❑ Yes ®No ❑ Yes 19 No <br /> acity 10k l0k 10k <br /> terial: Fiberglass Fiberglass Fiberglass <br /> nufacturer: Owens Corning Owens Corning Owens Corning <br /> Product Stored: Gasoline Gasoline Gasoline <br /> Wait time between applying <br /> pressure/vacuum/water and 10 min 1 10 min 10 min <br /> starting test: <br /> Test Start Time: 7:30 am 7:56 am 9:15 am <br /> Initial Reading(R,): 7"hg 7"hg 7"hg <br /> Test Find Time: 8:30 am 8:56 am 10:15 am <br /> Final Reading(Rr): 7"hg 7"hg 7"hg <br /> Test Duration: 1 hour 1 hour l hour <br /> Change in Reading(RF-Rr): None None None <br /> Pass/Fail Threshold or Criteria: No Detectable Loss No Detectable Loss No Detectable Loss <br /> Test Result: El Pass ❑ Fail D Pass ❑ Fail ff) Pass ❑ Fail <br /> Was sensor removed for testing? []Yes ® No❑NA ❑Yes M No ❑NA []Yes® No❑NA <br /> Was sensor properly replaced and ❑yes ❑No ®NA ❑Yes❑No ®NA ❑Yes❑No ®NA <br /> verified functional after testing? <br /> Comments --(include information on repairs made prior to testing, and recommended,follow-up for failed tests) <br /> "Sensor functionality was not confirmed.This procedure is not part of the Secondary Containment testing scope of work". <br /> ' Secondary containment systerns where the continuous monitoring automatically monitors both the primary and secondary <br /> containment, such as systems that are hydrostatically monitored or under constant vacuum,are exempt from periodic containment <br /> testing. (California Code of Regulations,Title 23,Section 2637(x)(6)1 <br /> 2:0'd 8888 826 80b swaI-sRS U01_4-)2;S a010J@S bZ:TT TT0E-2Z-NNf <br />