Laserfiche WebLink
Time In: 1.12 pm <br /> Time Out: 2:20 om <br /> �...Q .. C San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, CA 95205-6232 <br /> • �..• _ P• Telephone: (209)468-3420 Fax:(209)464-0138 Web:www.sigov.org/ehd <br /> 4�IFO';Rt� <br /> Food Program Official Inspection Report <br /> Name of Facility: DENNYS#1524 Date: 10/24/2016 <br /> Address: 3718 TRACY BLVD,TRACY 95376 <br /> Owner/Operator: BILL&EBBIE SCHAEFER Telephone: (559)313-5388 <br /> Program Element: 1626-RESTAURANT/BAR 101 +SEATS <br /> Inspection Type: ROUTINE INSPECTION -Operating Permit Reinspection on or after: 11/07/2016 <br /> VIOLATIONS AND CORRECTIVE ACTIONS <br /> Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code commencing with section 7; <br /> 113700.All violations must be corrected within specified timeframe. Violations that are classified as"MAJOR"pose an immediate threat to public health <br /> and have the potential to cause foodborne illness.All major violations must be corrected immediately.Non-compliance may warrant immediate closure of <br /> the food facility. <br /> #7 Hot and Cold Holding Temperatures MAJOR <br /> OBSERVATIONS:Reach-in/egg prep table refrigerator's temperature is 59F and food inside is between 49-59F. Discard all <br /> food above 50F or discard after 4 hours of being placed in the refrigerator. Correct immediately. <br /> Chicken noodle soup on prep line is 121 F. Maintain soup at or above 135F. Removed. <br /> CALCODE DESCRIPTION:Potentially hazardous foods shall be held at or below 41/45°F or at or above 135°F. (113996, 113998, <br /> 114037, 114343(a)) <br /> #27 Food Protected from Contamination <br /> OBSERVATIONS:Food in the freezer are uncovered. Provide covers today. <br /> CALCODE DESCRIPTION:All food shall be separated and protected from contamination. (113984(a, b, c,d, 0, 113986, 114060, <br /> 114067(a, d,e,j), 114069(a,b), 114077, 114089.1 (c), 114143(c)) <br /> #41 Plumbing Maintained;Approved Back Flow Device <br /> OBSERVATIONS:Hand sink drips and has tape wrapped around it at dessert station <br /> CALCODE DESCRIPTION: The potable water supply shall be protected with a backflow or back siphonage protection device,as required <br /> by applicable plumbing codes. (114192)All plumbing and plumbing fixtures shall be installed in compliance with local plumbing <br /> ordinances, shall be maintained so as to prevent any contamination,and shall be kept clean,fully operative,and in good repair. Any hose <br /> used for conveying potable water shall be of approved materials,labeled,properly stored,and used for no other purpose. (114171, <br /> 114189.1, 114190, 114193, 114193.1, 114199, 114201, 114269) <br /> #45 Floors,Walls, Ceilings; Clean and Maintained <br /> OBSERVATIONS:Wall at pass thru window has a metal stripping that is coming loose. Repair in 2 weeks. <br /> CALCODE DESCRIPTION: The walls/ceilings shall have durable,smooth,nonabsorbent,light-colored,and washable surfaces. All floor <br /> surfaces, other than the customer service areas, shall be approved, smooth, durable and made of nonabsorbent material that is easily <br /> cleanable.Approved base coving shall be provided in all areas,except customer service areas and where food is stored in original <br /> unopened containers. Food facilities shall be fully enclosed. All food facilities shall be kept clean and in good repair. (114143(d), <br /> 114266, 114268, 114268.1, 114271, 114272) <br /> FA0003041 PRO161134 SCO01 10/24/2016 <br /> EHD 16-23 Rev.06/30/15 Page 1 of 2 Food Program OIR <br />