Laserfiche WebLink
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209) 468-3420 Fax: (209) 468-3433 Web:www.sjgov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> J & L MARKET 8115 S EL DORADO ST FRENCH CAMP May 30 2018 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I, CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 209 CCR 2715(c) Designated operator did not inspect all required items and/or the inspection reports not completed. <br /> The designated operator failed to document all the alarms from the attached alarm history on the February 2018 <br /> designated operator monthly inspection report and failed to check that they were responded to appropriately. The <br /> 1/24/18 91 STP sump fuel alarm was documented, but the designated operator did not verify that the alarm was <br /> properly responded to and did not document that an inspection of the sump was conducted. At the time of inspection <br /> the 91 STP sump was observed to contain over 50 gallons of liquid and the sensor was on its side, not in alarm and <br /> unable to detect a leak. During the monthly inspection, the designated operator shall review the alarm history for the <br /> previous month, check that each alarm was documented and responded to appropriately, and attach a copy of the <br /> alarm history with documentation taken in response to any alarms to the monthly report. Ensure that designated <br /> operators performing monthly inspections at this facility are including all of the required information on the reports. <br /> This is a Class II violation. <br /> 211 CCR 2715(f)(2) Designated operator employee training not performed or log not kept. <br /> The designated operator employee training for Erica Romero was last performed on 1/16/17 and was not current. Ms. <br /> Romero was the only employee on site at the start of inspection. The designated operator shall train facility <br /> employees for which he or she is responsible in the proper operation and maintenance of the UST system once every <br /> 12 months. The training shall include, but is not limited to: <br /> 1. Operation of the UST system in a manner consistent with the facility's best management practices <br /> 2. Employee's role with regard to monitoring equipment as specified in the facility's monitoring plan <br /> 3. Employee's role with regard to spills and overfills as specified in the facility's response plan <br /> 4. Name of the contact person(s) for emergencies and monitoring equipment alarms <br /> Ensure that employees have been trained by the designated operator, maintain the list on site, and submit a copy of <br /> the updated training records to the EHD. <br /> This is a Class II violation. <br /> 302 HSC 25291(b) UST system incapable of detecting leak from primary into secondary containment(pre-Jul 2003). <br /> The 91 STP sump sensor was laying on its side in over 50 gallons of liquid and not located to detect a leak at the <br /> earliest opportunity. The sensor passed functionality testing during the monitoring certification. The monitoring <br /> system must be capable of detecting a leak from primary containment into secondary containment at all times. The <br /> sensor was relocated upright to the lowest point of the sump by the service technician. Ensure that all monitoring <br /> equipment is maintained to detect a leak at the earliest opportunity. <br /> This was corrected on site. <br /> This is a minor violation. <br /> FA0000110 PR0231563 SCO01 05/30/2018 <br /> EHD 23-01 Rev.09/22/16 Page 6 of 8 Underground Storage Tank Program OIR <br />