My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2010 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MANTHEY
>
3408
>
2300 - Underground Storage Tank Program
>
PR0517521
>
COMPLIANCE INFO 2010 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/14/2019 3:39:19 PM
Creation date
5/7/2019 10:21:43 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010 - 2018
RECORD_ID
PR0517521
PE
2361
FACILITY_ID
FA0013484
FACILITY_NAME
FOOD 4 LESS FUEL CENTER*
STREET_NUMBER
3408
STREET_NAME
MANTHEY
STREET_TYPE
RD
City
STOCKTON
Zip
95206
APN
16422011
CURRENT_STATUS
01
SITE_LOCATION
3408 MANTHEY RD
P_LOCATION
01
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
383
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
` RECEIVED <br /> JAN 0 8 2016 <br /> 9. FILL RISER CONTAINMENT SUMP TESTING <br /> Facility is Not Equipped With Fill Riser Containment Sums �- I <br /> Sumps ❑ - 'I C AL <br /> Fill Riser Containment Sumps are Present, but were Not Tested ❑ °�f-rv=-= CTR4 NOT <br /> Test Method Developed By: ❑Sump Manufacturer ® Industry Standard ❑ Professional Frigineer <br /> ❑Other(.Specify) <br /> Test Method Used: ❑ Pressure ❑Vacuum ® Hydrostatic <br /> ❑Other(Spec4j,) <br /> Test Equipment Used: Incon Sump Tester Equipment Resolution: +i-0.002" <br /> Fill Sump 9:87:= Fill Sump H 91 <br /> -Sump Diameter: 42" 42" <br /> Sump Depth: 64" 64" <br /> Height from Tank Top to Top of 19" 18" <br /> Hi <br /> hestPiping Penetration: <br /> Height from Tank Top to Lowest " <br /> Electrical Penetration: '- <br /> 2 <br /> Condition of sump prior to Good Good <br /> testing: <br /> Portion of Sump Tested 2"above piping, 2"above piping <br /> Sump Material: Fiberglass Fiber <br /> Wait time between applying <br /> pressure/vacuum/water and 30 minutes 311 minutes <br /> starting test: <br /> Test Start Time: 9:18 am 9:18 am <br /> initial Reading(Rj): 3.4627 4.9219 <br /> Test End Time: 9:33 am 9:33 am <br /> Final Reading(RF): 3.4629 4.9221 <br /> Test Duration: 15 min. 15 min. <br /> Change in Reading(RF-R,): 0.0002 0.0002 <br /> Pass/Fail Threshold or Criteria: +/-0,002" +/.0,002" <br /> Test Result: © Pass ❑Fail 0 Pass ❑ Fail <br /> Is there a sensor in the sump? ®Yes ❑No ®Yes ❑No <br /> Does the sensor alarm when <br /> either product or water is ❑ Yes❑ No®NA ❑Yes❑No®NA <br /> detected? <br /> Was sensor removed for testing? O Yes❑No❑NA ®Yes❑No❑NA <br /> Was sensor properly replaced and ®Yes❑No❑ NA ®Yes❑No❑ NA <br /> verified functional after testing? <br /> Comments — (include information on repairs made prior to felting, curd recommended follow-up for.iailed tests) <br /> Sensor functionality was not confirmed.This procedure is not part of the Secondary Containment testing scope of work <br />
The URL can be used to link to this page
Your browser does not support the video tag.