My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2010 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MANTHEY
>
3408
>
2300 - Underground Storage Tank Program
>
PR0517521
>
COMPLIANCE INFO 2010 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/14/2019 3:39:19 PM
Creation date
5/7/2019 10:21:43 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010 - 2018
RECORD_ID
PR0517521
PE
2361
FACILITY_ID
FA0013484
FACILITY_NAME
FOOD 4 LESS FUEL CENTER*
STREET_NUMBER
3408
STREET_NAME
MANTHEY
STREET_TYPE
RD
City
STOCKTON
Zip
95206
APN
16422011
CURRENT_STATUS
01
SITE_LOCATION
3408 MANTHEY RD
P_LOCATION
01
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
383
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department ME N 0ED <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 r _j2 --15 <br /> Telephone: (209)468-3420 Fax:(209)468-3433 Web:www.sigov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> FOOD 4 LESS FUEL CENTER* 3408 MANTHEY RD, STOCKTON December 21, 2015 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item # Remarks <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed. <br /> An accurate UST Monitoring Site Plan was not submitted. Provide a legend to the site plan. A site plan must be <br /> submitted identifying the locations where monitoring will be performed. Immediately log into the California <br /> Environmental Reporting System(CERS) at http://cers.calepa.ca.gov/and upload a copy of the revised UST <br /> Monitoring Site Plan. <br /> This is a minor violation. <br /> 126 HSC 25404(e)(4) Failed to report program data electronically. <br /> The Response Plan was not submitted to the the California Electronic Reporting System(CERS). Beginning <br /> January 1, 2014, all businesses are required to submit all new(or any changes to existing) UST information, <br /> including: UST Monitoring Site Plan, UST Certification of Financial Responsibility, UST Response Plan, UST <br /> Owner/Operator Written Agreement (if applicable), UST Letter from Chief Financial Officer, and Owner Statement of <br /> Designated UST Operator Compliance online to the CERS at http://cers.calepa.ca.gov. Be sure to include any <br /> other relevant activities and required fields. <br /> This is a repeat violation, Class II. <br /> 319 HSC 25291(e)Water in secondary containment not removed, analyzed, and properly disposed of(pre-Jul 2003). <br /> Liquid was observed in the 87 submersible turbine pump (STP) sump and in the 91 fill sump. If water could enter <br /> into the secondary containment by precipitation or infiltration, it must be removed and disposed of properly. The <br /> service technician removed approximately one gallon of liquid from the 87 STP sump and less than one cup of liquid <br /> from the 91 fill sump and returned the sensors to their proper location. Ensure that all sumps and annular spaces <br /> are maintained free of liquid. <br /> Corrected on site. <br /> This is a repeat violation, Class ll. <br /> Overall Inspection Comments: <br /> On site on December 21, 2015, to conduct a routine monitoring system certification, spill container, and line leak <br /> detector inspection. A cold start was scheduled for today for Service Request SR0072611, but was performed <br /> on December 10, 2015; no alarm history was available prior to the cold start on December 10, 2015. <br /> A partial list of violations was left with Mr. Jesus Jurado on the day of the inspection. A final inspection report <br /> will be sent at a later date. <br /> During the inspection on December 21, 2015, the service technician replaced the 87 product fill sump <br /> VR794380-208 sensor, like for like, since the wiring on the sensor was decaying. <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by January 21, 2016. <br /> Received by Inspector: Phone: Date: <br /> (initial): VICKI MCCARTNEY, Senior REHS (209)468-9852 12/21/2015 <br /> Page 5 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.