My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2007 - 2009
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MANTHEY
>
3408
>
2300 - Underground Storage Tank Program
>
PR0517521
>
COMPLIANCE INFO 2007 - 2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/12/2023 4:44:25 PM
Creation date
5/7/2019 4:02:30 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007 - 2009
RECORD_ID
PR0517521
PE
2361
FACILITY_ID
FA0013484
FACILITY_NAME
FOOD 4 LESS FUEL CENTER*
STREET_NUMBER
3408
STREET_NAME
MANTHEY
STREET_TYPE
RD
City
STOCKTON
Zip
95206
APN
16422011
CURRENT_STATUS
01
SITE_LOCATION
3408 MANTHEY RD
P_LOCATION
01
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
277
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br /> A Results of Testing/Servicing <br /> r <br /> Software Version Installed:_/ZZ. C C0 <br /> Complete the following checklist: <br /> Yes ❑ No* Is the audible alarm operational? <br /> A Yes ❑ No* Is the visual alarm operational? <br /> Yes ❑ No* Were all sensors visually inspected, functionally tested, and confirmed operational? <br /> Yes ❑ No* Were all sensors installed at lowest point of secondarypontainnunt and_.,positioned so that other equipment will <br /> not interfere with their proper operation? <br /> - ` <br /> ❑ Yes If alarms area reldytd- to-.a' remote monitoring station, is sll do Anic`tions equipment (e.g. modem) <br /> N/A, Aperational? •.�.��1 <br /> Yes 0 No* For pressurized piping systems,-does;the�ltrrbine•automatically shpt down if the piping secondary containment <br /> L3 N/A' monitoring system detects a leak, fails to operate, or is electrically disb�nected? If yes: which sensors initiate <br /> positive shut-down? (Check all that apply)A Sump/Trench Sensors; Dispenser Containment Sensors. <br /> Did you confirm positive shut-down due to leaks and sensor failure/disconnection? 16 Yes; ❑No. <br /> Yes ❑ No* For tank systems that utilize the monitoring system as the primary talik'overfill'warning device (i.e. no <br /> ❑•N/A' mechanical overfill prevention valve is installed)js the oJ�r rrVarning alarm visible and audible at the,tank <br /> fill point(s)and operating If so,at what 'percent of tank gapacity capacitydoes the alarm trigger? O % <br /> ❑ Yes* Uff No Was any monitoring equipment replaced? If yes identify specific sensors,probes, or other equipment replAced <br /> and list the manufacturer name and model for all re iacement arts in Section E,below. <br /> ❑ Yes* 8 No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) ❑ <br /> Product; ❑ Water. If yes,describe causes in Section E,below. <br /> X-yes ❑ No*. Was monitoring system set-up reviewed to ensure proper settings?Attach set!T.r -or4s,if applicable <br /> lb Yes ❑ No*. Is all monitoring equipment oerational per manufacturer's s e ' cations? <br /> * In Sec:,on E below,describe how and when these deficiencies were or will be corrected. <br /> E. Co ments• <br /> Y' a, <br /> Page 2 of 3 03/01 <br />
The URL can be used to link to this page
Your browser does not support the video tag.