FA0013484
FACILITY_NAME
FOOD 4 LESS FUEL CENTER*
STREET_NUMBER
3408
STREET_NAME
MANTHEY
STREET_TYPE
RD
City
STOCKTON
Zip
95206
APN
16422011
CURRENT_STATUS
01
SITE_LOCATION
3408 MANTHEY RD
P_LOCATION
01
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
284
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page 6 of 7 <br /> 8. ItL RISER CONTAINMENT SUMP TESTING <br /> Facility is Not Equipped With Fill Riser Containment Sumps ❑ <br /> Fill Riser Containment Sumps are Present,but were Not Tested ❑ <br /> Test Method Developed By: ❑Sump Manufacturer X Industry Standard ❑Professional Engineer <br /> ❑Other(Spec) <br /> Test Method Used: ❑Pressure ❑Vacuum X Hydrostatic <br /> ❑Other(Spec) <br /> Test Equipment Used:Incon TS-STS Equipment Resolution: <br /> Fill Sump#P.F.S. Fill Sump#R.F.S. Fill Sump# Fill Sump# <br /> Sump Diameter: 42" 42" <br /> Sump Depth: 60" 62" <br /> Height from Tank Top to Top of 18" 18" <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest 31" 32" <br /> Electrical Penetration: <br /> Condition of sump prior to Clean Clean <br /> testing: <br /> Portion of Sump Tested Full Full <br /> Sump Material: Fiberglass Fiberglass <br /> Wait time between applying 15 minutes 15 minutes <br /> pressure/vacuum/water and <br /> starting test: <br /> Test Start Time: 9:24 am 9:24 am <br /> Initial Reading(RI): 1.2551" 0.6409" <br /> Test End Time: 9:40 am 9:40 am <br /> Final Reading(RF): 1.2550" 0.6409" <br /> Test Duration: 16 minutes 16 minutes <br /> Chane in Reading(RF-RI): .0001"loss No change <br /> Pass/Fail Threshold or Criteria: Loss<.002"— ass Loss<.002"— ass <br /> Test Result: X Pass ❑Fail X Pass ❑Fail ❑ Pass ❑Fail ❑ Pass ❑Fail <br /> Is there a sensor in the sump? X Yes ❑No X Yes ❑No ❑Yes ❑No ❑Yes ❑No <br /> Does the sensor alarm when <br /> either product or water is X Yes ❑No ❑NA X Yes ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> detected? <br /> Was sensor removed for testing? X Yes ❑No ❑NA X Yes ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> Was sensor properly replaced and X Yes ❑No ❑NA X Yes ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> verified functional after testin ? <br /> Comments—(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />