My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2002 - 2006
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MANTHEY
>
3408
>
2300 - Underground Storage Tank Program
>
PR0517521
>
COMPLIANCE INFO 2002 - 2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/14/2019 3:00:07 PM
Creation date
5/8/2019 1:59:52 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002 - 2006
RECORD_ID
PR0517521
PE
2361
FACILITY_ID
FA0013484
FACILITY_NAME
FOOD 4 LESS FUEL CENTER*
STREET_NUMBER
3408
STREET_NAME
MANTHEY
STREET_TYPE
RD
City
STOCKTON
Zip
95206
APN
16422011
CURRENT_STATUS
01
SITE_LOCATION
3408 MANTHEY RD
P_LOCATION
01
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
284
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page 6 of 7 <br /> 8. FELL RISER CONTA gAMNT SUMP TESTING <br /> Facility is Not Equipped With Fill Riser Containment Suns s ❑ <br /> Fill Riser Containment Sumps are Present but were Not Tested ❑ <br /> Test Method.Developed i3y: ❑ Sump Manufacturer X Industry Standard Q Professional Engineer <br /> F1 Other(Specify) <br /> Test Method Used: 0 Pressure ❑Vacuum X Hydrostatic <br /> ❑Other(Specify) <br /> Test Equipment Used:Incon TS-STS Equipment Resolution: <br /> Fill Sum #P.F.S. Fill Sam #R.F.S. Fill Sum # Fill Sum # <br /> Sump Diameter: 42" 42" <br /> Sum .Dc the 60" 62" <br /> Height from Tank Top to Top of l 8" 181t <br /> Hi est Piping Penetration: <br /> Height from Tank Top to Lowest 31" 32" <br /> Electrical Penetration: <br /> Condition of sump prior to Clean Clean <br /> testin <br /> Portion of SAMp Tested Full pup <br /> Sump Material: Fiber lass Fiberglass <br /> Wait time between applying 15 minutes 15 minutes <br /> pressure/vacuum/water and <br /> startin test: <br /> Test Start Time: 9:24 am 9:24 am <br /> Initial Readin R : 1.2551" 0.6409" <br /> Test End Time: 9:40 am 9:40 am <br /> Final Read' RF : 1.2550" 0.6409" <br /> Test Duration: 16 minutes 16 minutes <br /> Change in Readin, Rr-R, : .0001"loss No chan e <br /> Pass/Fail Threshold or Criteria: Loss<.002"= ass Loss<.002"— ass <br /> Test Result: X Pass Q Fail X Pass Q Fail 17 Pass Ll Fail 12 Pass Cl Fail <br /> Is there a sensor inthe sump? X Yes C1 No X Yes ❑No ❑Yes Cl No ❑Yes ❑No <br /> Does the sensor alarm when <br /> either product or water is X Yes ❑No ❑NA X Yes L1 No ❑NA ❑Yes ❑No ❑NA, ❑Yes ❑No ❑NA <br /> detected? <br /> Was sensor removed for testing? X Yes 0 No ❑NA X Yes ❑No ❑NA ❑Yes ❑No ❑NA ❑Yes O No ❑NA <br /> Was sensor properly repIacod and <br /> verified fu.nctianal after testing? X Yes ❑No ❑NA X Yes El fl NA ❑Yes ❑No ❑.NA ❑Yes ❑No ❑NA <br /> COMMents—(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />