My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2002 - 2006
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MANTHEY
>
3408
>
2300 - Underground Storage Tank Program
>
PR0517521
>
COMPLIANCE INFO 2002 - 2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/14/2019 3:00:07 PM
Creation date
5/8/2019 1:59:52 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002 - 2006
RECORD_ID
PR0517521
PE
2361
FACILITY_ID
FA0013484
FACILITY_NAME
FOOD 4 LESS FUEL CENTER*
STREET_NUMBER
3408
STREET_NAME
MANTHEY
STREET_TYPE
RD
City
STOCKTON
Zip
95206
APN
16422011
CURRENT_STATUS
01
SITE_LOCATION
3408 MANTHEY RD
P_LOCATION
01
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
284
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page 5 of 7 <br /> 7. UNDER-DISPENSER CONTAINMENT C TESTING <br /> Test Method Developed By: 7 UDC Manufacturer X industry Standard D Professional Fngineer <br /> ❑Other(Specify) <br /> Test Method Used: D Pressure ❑Vacuum X Hydrostatic <br /> 11 Other(Sped) <br /> Test Equipment Used: ancon TS STS Frquipmant Resolution: <br /> UDC#3-10 UDC#1,2 UDC# UDC# <br /> UDC Manufacturer: Owens Coming Environ <br /> UDC Material_ Fibe lass Fiberglass <br /> UDC Depth: 3l <br /> Height from.UDC Bottom to Top 10" <br /> of Highest Piping Penetration; <br /> Height from UDC Bottom to 4" <br /> Lowest Electrical Penetration: <br /> Condition of UDC prior to Clean <br /> tcstin . <br /> Portion of UDC Tested Full <br /> Does turbine shut down when <br /> UDC sensor detects liquid(both. X Yes D No [INA X Yes ❑No 1]NA Dyes ❑No FI NA D Yes ❑No ❑NA <br /> roduct and water)?' <br /> Turbine shutdown.res onse time 2 Seconds 2 Seconds <br /> Is systemprogrammed for fail- X Yes ❑ No ❑NA No DNA X Yes ❑No ❑NA 11 O Yes ❑No I:1 NA <br /> safe shutdown?* ❑Yes <br /> Was fail-safe verified to be X Yes ❑No ❑NA X Yes U No ❑NA F-1No 11 NA ❑Yes ❑No (1 NA <br /> erational?o D Yes <br /> Wait time between applying No test 15 minutes <br /> pressure/vacuum/water and <br /> starting test <br /> Test Start Time: 1:56 pm <br /> Initial Readin �: 1.2385" <br /> Test End Time: 2:11 <br /> Final Reading Rp : 1.2552" <br /> Test Duration: 15 minutes <br /> Chan p in Reading R -R 0 167"increase <br /> Pass/Fail.Threshold or Criteria: Loss<.002"=pass <br /> Test Result: C Pass 0 Feil X Pass ©Fail 0 Pass C7 Fall ❑ Pass ❑Fail <br /> Was sensor removed for testing? ❑Yes C No ❑NA X Yes i7 No ❑NA ❑Yes ❑No C NA 17 Yes ❑No D NA <br /> Was sensor properly repleted and No❑Yea El No ❑NA X Yes ❑No ❑NA 1C Yes ❑No 11 NA 11Y C1 11 NA <br /> verified functional after testing? <br /> Comments—(include information on rc airs made Rrior to tcstin , and recommended follow-u or fatted tesrs) <br /> Test boots need t be r aird the econdary in order Qtest. <br /> 1 If the entire depth of the UDC is not tested,specify how much was tested_ If the answer to�n�of the questions indicated.with an <br /> asterisk(•)is"NO"or"NA'",the entire UDC must be tested. (See SWRCB LG-1 60) <br />
The URL can be used to link to this page
Your browser does not support the video tag.