Laserfiche WebLink
f UD PROGRAM CONSOLIDATED FOIN <br /> UNDERGROUND STORAGE TANK <br /> MONITORING PLAN-(Paste 1 of 2 <br /> �,/� <br /> TYPE OF ACTION ❑ 1.NEW PLAN ❑ 2.CHANGE OF INFORMATION 9'l. A+j N U 490.1. <br /> PLAN TYPE ❑ 1.MONITORING IS IDENTICAL FOR ALL USTs AT THIS FACILITY. 490-2 <br /> (Check one item only) ❑ 2.THIS PLAN COVERS ONLY THE FOLLOWING UST SYSTEM(S): <br /> I. FACILITY INFORMATION <br /> FAQILITY ID#(A>;encv Use Only) _ 0FT <br /> 1. <br /> BUSINESS NAME(Same as Facility Name or DBA) �t 3. <br /> / q.-I STQE -T /kt cp Awl P M - IL 3S E NTEJ-P(,LSF- LLc- <br /> BUSINESS SITE ADDRESS 103. 1 C[Ty 104. <br /> 1\00 S• NAlr,3 STLEET M Atilt CA , C q 33} <br /> II. EQUIPMENT TESTING AND PREVENTIVE MAINTENANCE <br /> Testing,preventive maintenance,and calibration of monitoring equipment(e.g.,sensors,probes,line leak detectors,etc.)must be performed at the frequency specified <br /> by the guipment manufacturers'instructions,or annually,whichever is more cent.Such work must be performed by qualified personnel.[23 CCR§2632,2634,26.3.8,26411 <br /> MONITORING E UIPMENT IS SERVICED 1.ANNUALLY ❑ 99.OTHERS i 490-3a. <br /> Q ( P��)� 490.36. <br /> III. MONITORING LOCATIONS <br /> ❑ 1.NEW SITE PLOT PLAN/MAP SUBMITTED WITH THIS PLAN 2.SITE PLOT PLAN/MAP PREVIOUSLY SUBMITTED (23 CCR§2632,2634] 490-4 <br /> IV. TANK MONITORING IS PERFORMED USING THE FOLLOWING METHOD(S) " eck that Ill <br /> 1.CONTINUOUS ELECTRONIC TANK MONITORING OF ANNULAR(INTERSTITIAL)SPACE(S)OR SECONDARY CONTAINMENT VAULT(S) 490-5. <br /> WITH AUDIBLE AND VISUAL ALARMS.[23 CCR§2632,2634] <br /> SECONDARY CONTAINMENT IS: J a.DRY ❑ b.LIQUID FILLED ❑ c.PRESSURIZED ❑ d.UNDER VACUUM 490.6. <br /> PANEL MANUFACTURER: I M E r*C-0 - R U D'T 490.7' MODEL#: Z L S _'�S n 490.8. <br /> LEAK SENSOR MANUFACTURER: V EE DfQ-^9100-T 490-9. MODEL#(S): 'j q lei 3 q n-4 t'1 q 490-10. <br /> ❑ 2.AUTOMATIC TANK GAUGING(ATG)SYSTEM USED TO MONITOR SINGLE WALL TANK(Sl.[23 CCR§26431 490-11. <br /> PANEL MANUFACTURER: _ 490.12' MODEL#: _ 490-13' <br /> IN-TANK PROBE MANUFACTURER: 490-14' MODEL#(S): 490-15. <br /> LEAK TEST FREQUENCY: 9a.CONTINUOUS ❑ b.DAILY/NIGHTLY ❑ c.WEEKLY 490-16. <br /> ❑ d.MONTHLY ❑ e.OTHER(Specify): 49x17' <br /> PROGRAMMED TESTS: _❑ a.0.1 h. ❑ b.0.2 h. ❑ c.OTHERS i 0-9118. <br /> g•P• g•P• _ (Specify): _ago-19. <br /> ❑ 3.MONTHLY STATISTICAL INVENTORY RECONCILIATION[23 CCR§2646.1] 490.20. <br /> ❑ 4.WEEKLY MANUAL TANK GAUGING(MTG)[23 CCR§26451 TESTING PERIOD: ❑ a.36 HOURS ❑ b.60 HOURS -490.21. <br /> 490.22._ <br /> ❑ 5.TANK INTEGRITY TESTING PER[23 CCR§2643.1] 490.23' <br /> FREQUENCY: ❑ a.ANNUALLY b.BIENNIALLY ❑ c.OTHERS 490.24' <br /> TEST <br /> - - -- --- - ❑ (Specify): ago 20_- <br /> ❑ <br /> 99.OTHER(Specify): V%wAL MOW IToR It�1�L- 49207. <br /> V. PIPE MONITORING IS PERFORMED USING THE FOLLOWING METHOD(S) t( heckall <br /> 1.CONTINUOUS MONITORING OF PIPE/PIPING SUMP(S)AND OTHER SECONDARY CONTAINMENT WITH AUDIBLE&VISUAL ALARMS. 490-2s. <br /> f23 <br /> SECONDARY CONTAINMENT IS: C.a.DRY ❑ b.LIQUID FILLED ❑ c.PRESSURIZED ❑ d.UNDER VACUUM 490.29. <br /> PANEL MANUFACTURER: VE�epe(--f,a 0T 49130. MODEL#: TL< -3. S'O 490.31. <br /> LEAK SENSOR MANUFACTURER: V'ElE DEP-- 0--ft-T 490.32' MODEL#(S): �q 3 o-3 3 490.33. <br /> PIPING LEAK ALARM TRIGGERS AUTOMATIC PUMP(i.e.,TURBINE)SHUTDOWN. a.YES [Ib.NO 490.34. <br /> FAILURE/DISCONNECTION OF THE MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. a.YES ❑ b.NO 490.35, <br /> 2.MECHANICAL LINE LEAK DETECTOR(MLLD)THAT ROUTINELY PERFORMS 3.0 g.p.h.LEAK TESTS AND RESTRICTS OR SHUTS OFF 490.36. <br /> PRODUCT FLOW WHEN A LEAK IS DETEC D.[23 CCR§26361 <br /> MLLD MANUFACTURER(S): PL-To-,p 49x37' MODEL#(S): 4V(Lb2.0p0kXQ ML p49138' <br /> ❑ 3.ELECTRONIC LINE LEAK DETECTOR(ELLD)THAT ROUTINELY PERFORMS 3.0 g p.h.LEAK TESTS.[23 CCR§2636] 490.39. <br /> ELLD MANUFACTURER(S): 490.40' MODEL#(S): 490-41' <br /> PROGRAMMED IN LINE LEAK TEST: ❑ a.MINIMUM MONTHLY 0.2 g.p.h. ❑ b.MINIMUM ANNUAL 0.1 g.p.h. 49042. <br /> ELLD DETECTION OF A PIPING LEAK TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑ a.YES ❑ b.NO 49043 <br /> ELLD FAILURE/DISCONNECTION TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑ a.YES ❑ b.NO 490.44. <br /> ❑ 4.PIPE INTEGRITY TESTING. -- - -- 490-45. <br /> TEST FREQUENCY: ❑ a.ANNUALLY b.EVERY 3 YEARS c.OTHERS i 490-46. <br /> -Q ❑ ❑ (Specify) _0-9°•0-7• <br /> ❑ 5.VISUAL PIPE MONITORING. 490-48. <br /> FREQUENCY: a.DAILY ❑ b.WEEKLY ❑ c.MIN.MONTHLY&EACH TIME SYSTEM OPERATED* 490.49. <br /> •Allowed fa monitoring of unbwied em«smeYBmmatwAy!l�i�nB only HSc§25281.5(6x3) <br /> ❑ 6.SUCTION PIPING MEETS EXEMPTION CRITERIA.(23 CCR§2636(.x3)) 490-50' <br /> ❑ 7.NO REGULATED PIPING PER HEALTH AND SAFETY CODE,DIVISION 20,CHAPTER 6.7 IS CONNECTED TO THE TANK SYSTEM. 490-51. <br /> ❑ 99.OTHER S i 490 s2. <br /> 49153. <br /> UPCF UST-D(12/2007)-1/4 www.unidocs.org <br />