Laserfiche WebLink
r_. <br />a <br />a <br />UNDERGROUND STORAGE TANK <br />MONITORING PLAN - PAGE 2 <br />VL DISPENSER MONITORING <br />MONITORING OF AREAS BENEATH DISPENSER(S) IS PERFORMED USING THE FOLLOWING METHOD(S) (Check all that apply) Myo. <br />❑ 1. CONTINUOUS ELECTRONIC MON1TnR,ING OF UNDER DISPENSER CONTAINMENT (UDC) <br />PANEL MANUFACTURER: M51. MODEL #: 7 Q 43i D-^2 Ct M52. <br />LEAK SENSOR MANUFACTURER: V E E DfMR (Z O DT M53 MODEL #(S): -T L 3 5D M54. <br />WILL DETECTION OF A LEAK INTO THE UDC TRIGGER AUDIBLE AND VISUAL ALARMS? U a. YES ❑ b. NO Mss. <br />WILL A UDC LEAK ALARM TRIGGER AUTOMATIC PUMP SHUTDOWN? a. YES ❑ b. NO M56. <br />WILL FAILURE/DISCONNECTION OF UDC MONITORING SYSTEM TRIGGER AUTOMATIC PUMP SHUTDOWN? a. YES ❑ b. NO M57. <br />❑ 2. MECHANICAL ASSEMBLY (e.g., FLOAT AND CHAIN ASSEMBLY) IN UDC TRIPS SHEAR VALVE IN CASE OF LEAK <br />ASSEMBLY MANUFACTURER: M" MODEL #(S): M59. <br />❑ 3.VISUAL MONITORING DONE: ❑ a. DAILY ❑ b. WEEKLY (Requires agency approval) M% <br />❑ 4. NO DISPENSERS <br />❑ 99. OTHER (Specify) M61. <br />_ :;VII: -:ENHANCED. LEAK; DETECTION <br />❑ 1. WE HAVE BEEN NOTIFIED BY THE STATE WATER RESOURCES CONTROL BOARD THAT WE MUST IMPLEMENT ENHANCED LEAK M70. <br />DETECTION (ELD) FOR THE UST(S) COVERED BY THIS PLAN, PER 23 CCR §2644.1, ELD IS PERFORMED EVERY 36 MONTHS AS REQUIRED <br />VIII. TRAINING <br />REFERENCE DOCUMENTS MAINTAINED AT FACILITY (Check all that apply) Mao. <br />1. THIS UNDERGROUND STORAGE TANK MONITORING PLAN (Required) <br />2. OPERATING MANUALS FOR ELECTRONIC MONITORING EQUIPMENT (Required) <br />3. THE FACILITY'S BEST MANAGEMENT PRACTICES (Required as of 1/01/2005) <br />4. CALIFORNIA UNDERGROUND STORAGE TANK REGULATIONS <br />5. V CALIFORNIA UNDERGROUND STORAGE TANK LAW <br />6. ❑ STATE WATER RESOURCES CONTROL BOARD (SWRCB) PUBLICATION: "HANDBOOK FOR TANK OWNERS - MANUAL AND <br />STATISTICAL INVENTORY RECONCILIATION" <br />7. ❑ SWRCB PUBLICATION: "WEEKLY MANUAL TANK GAUGING FOR SMALL UNDERGROUND STORAGE TANKS" <br />99. ❑ OTHER (Specify): Mai. <br />Personnel with UST monitoring responsibilities are familiar with all of the above documents relevant to their job duties and can access those documents when needed. <br />By January 1, 2005 this facility will have a "Designated UST Operator" who has passed the operator exam administered by the International Code Council (ICC). By <br />January 1, 2005, and annually thereafter, the "Designated UST Operator" will train facility employees in the proper operation and maintenance of the UST systems. <br />This training will include, but is not limited to, the following: <br />➢ Operation of the UST systems in a manner consistent with the facility's best management practices. <br />➢ The facility employee's role with regard to the leak detection equipment. <br />➢ The facility employee's role with regard to spills and overfills. <br />➢ Whom to contact for emergencies and leak detection alarms. <br />For facility employees hired on or after January 1, 2005, the initial training will be conducted within30 days of the date of hire. <br />IX-COMMENTS/ADDITIONAL:INFORIGIATI01 . <br />Please use this section to include any additional UST system monitoring -related information (e.g., additional information required by youli): Mas. <br />Avlcf MI C_ QUh'IQ SihV r (5FF WNLL 0C -C -U W}IETI1cti6iL ; �tdt-et0a*S <br />(,F_LEASE IS SF_ NICP IW 'TU L8)P!E Sterne /dew -x <br />�LELeASr- IS SEtJIED aC OISVENSEIL W/S+-wS� <br />11AU,A-WL%NL SyI'TE^^ IS J)LSe-ONNEL:TED 01- FktL-s [N ANY W 4 CPM,SAF- C) <br />X..PERSONNEL RESPONSIBILITIES <br />AS OF I/I/05, THE "DESIGNATED UST OPERATOR" IDENTIFIED IN SECTION III OF THE CURRENT UST OPERATING PERMIT APPLICATION — <br />FACILITY FORM WILL HAVE ULTIMATE AUTHORITY FOR PERFORMING THE MONITORING ACTIVITIES AND MAINTAINING LEAK DETECTION <br />EQUIPMENT COVERED BY THIS PLAN, AND WILL PERFORM AND DOCUMENT MINIMUM MONTHLY VISUAL INSPECTIONS OF THE FACILITY'S <br />UST SYSTEMS IN ACCORDANCE WITH 23 CCR § 2715(b). <br />XI OWNER/OPERATOR SIGNATURE `. <br />CERTIFICATION: I certify that the information provided herein is true and accurate to the best of my knowledge. <br />OWNER/OPERATOR SIGNATURE REPRESENTING <br />DATE: M91. <br />❑ Owner M9o. <br />I 1 <br />❑ Operator <br />OWNER/OPERATOR NAME (print): M92. <br />OWNER/OPERATOR TITLE: M93. <br />kuL OEEP C- SH Kr4P- <br />MPrk A6:0 <br />(Agency Use Only) This plan has been reviewed and: ❑ Approved ❑ Approved With Conditions ❑ Disapproved <br />Local Agency Signature: t }-fa Date: 3 <br />Comments/Special Conditions: <br />SJCEHD-d (07/03) - 3/4 <br />07/23/03 <br />M1 <br />