COMPLIANCE INFO 2010 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1100
>
2300 - Underground Storage Tank Program
>
PR0506504
>
COMPLIANCE INFO 2010 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/20/2023 11:22:26 AM
Creation date
5/13/2019 8:45:42 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010 - 2018
RECORD_ID
PR0506504
PE
2361
FACILITY_ID
FA0007464
FACILITY_NAME
MAIN STREET ARCO AM PM*
STREET_NUMBER
1100
Direction
S
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95337
APN
22119062
CURRENT_STATUS
01
SITE_LOCATION
1100 S MAIN ST
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
296
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax: (209) 468-3433 Web:www.si og v.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> MAIN STREET ARCO AM PMk 1 1100 S MAIN ST MANTECA March 14 2016 <br /> UST System Observations <br /> 321 CCR 2636(c)(1) All releases in secondary piping do not flow to a collection sump j V ❑R --i COS <br /> 322 CCR 2636(f)(2) Line leak detector not installed :-i V R n COS <br /> 323 CCR 2636(f)(2) Leak detector failed to detect a 3.0 gph leak at 10 psi ❑V ❑R COS <br /> 324 CCR 2635(b) No spill bucket installed or failed to provide a means to keep it empty c V Ej R COS <br /> 325 CCR 2635(b) Spill container failed to contain a minimum capacity of five gallons ❑V ❑R L,COS <br /> 326 CCR 2635(b)(2) Overfill prevention system not present or failed to meet overfill requirements V ❑R ❑COS <br /> 327 CCR 2635(b)(2) Overfill prevention was overridden ❑V ❑R ❑COS <br /> 328 HSC 25283.5 Unburied below grade UST failed to meet exemption status ❑V ❑R ❑COS <br /> 329 CCR 2717.1(g) Tampered with red tag ❑V ❑R ❑COS <br /> 330 CCR 2717.1(f) Deposited petroleum into a red tagged UST ❑V ❑R ❑COS <br /> 331 HSC 25299(f)(2) Tampered with or disabled leak detection devices or alarms ❑V E R -_i COS <br /> 332 CCR 2631.1 UST system not compatible with the substance stored n V ❑R ❑COS <br /> 333 HSC 25298(b) Failed to comply with temporary closure requirements ❑V R COS <br /> 334 HSC 25298(c) Failed to comply with permanent closure requirements V R COS <br /> Non-Pressurized Piping <br /> 401 CCR 2636(2)(3) Suction piping not properly sloped or incorrectly located check valve ❑V E R COS <br /> 402 CCR 2643(d) Daily monitoring of suction pipe(pre-Jan 1984)not performed ❑V E R COS <br /> 403 CCR 2643(d) Triennial 0.1 gph line test for conventional suction piping not performed(pre-January 1984) ❑V ❑R i COS <br /> 404 CCR 2643(e) Biennial 0 1 gph test for gravity piping not performed (pre-January 1984) V R COS <br /> Other Violations <br /> 2010 See below Unlisted Administration/Documentation violation ❑V ❑R ❑COS <br /> 2030 See below Unlisted Operations/Maintenance violation ❑V c R ❑COS <br /> 2060 See below Unlisted Design/Construction violation ❑V c R i COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS Il,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 113 CCR 2638(d) Failed to submit monitoring system certification test report within 30 days. <br /> A monitoring system certification, leak detector testing, and spill container testing were performed on 3-17-15. A test <br /> report has not been submitted to the EHD or the California Environmental Reporting System (CERS). A copy of the <br /> test report must be submitted within 30 days of the test. Immediately provide this report to the EHD. <br /> This is a Class II violation. <br /> Page 3 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.