Sent By: RHL DESIGN GROUP; 7077659908; Apr-2P ^4 10:49AM; Page 17/17 <br /> Date April 16.2004 <br /> EMERGENCY RESPONSE PLAN <br /> UNDERGROUND STORAGE TANK MONITORING PROGRAM <br /> This monitoring program must be kept at the UST location at all times. The information on this monitoring program are <br /> conditions of the operating permit. The permit holder must notify.San Joaquin County Public Health Services within 30 days of any <br /> changes to the monitoring procedures,unless required to obtain approval before making the change. <br /> Required by Sections 2632(d)and 2641(h)CCR. <br /> Facility Name Safeway Store#2707 <br /> Facility Address 6425 N. Pacific Ave.Stockton <br /> 1. If an unauthorized release occurs,how will the hazardous substance be cleaned up? Note: <br /> If released hazardous substances reach the environment, increase the fire or explosion <br /> hazard, are not cleaned up from the secondary containment within 8 hours, or <br /> deteriorate the secondary containment, then San 7oaouin County Public Health Services <br /> must be notified within 24 hours. For small spills the on site personnel will use <br /> absorbent material to clean up the released material In the event of a larger spill the <br /> operator will call 9-1-1 (if necessary), the Safeway Store Manager and Tanknology to assist <br /> in the emergency. <br /> 2. Describe the proposed methods and equipment to be used for removing and properly <br /> disposing of any hazardous substances. <br /> Spent absorbent will be placed into an approved container and disposed of in accordance <br /> with all Local. State. and Federal laws and regulations The operator is responsible for <br /> coordinating the disposal of all used absorbent. Any additional equipment will be provided <br /> be the responding contractor. <br /> 3. Describe the location and availability of the required cleanup equipment in item 2 above. <br /> Absorbent is maintained on site and restocked as needed by the site personnel The <br /> contractor maintains any additional equipment and available on an as needed basis <br /> 4. Describe the maintenance schedule for the cleanup equipment. <br /> Absorbent is inspected weekly and reordered as needed Any equipment provided by the <br /> responding contractor is the responsibility of that contractor. <br /> 5. List the name(s) and title(s) of the person(s)responsible for authorizing any work necessary <br /> under the response plan: <br /> Stan Olea/Fuel Operations Manager <br /> Heather Moon/Safeway Food Safety&Environmental Compliance <br /> Safeway Mon.doc <br />