My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2004 - 2008
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
6425
>
2300 - Underground Storage Tank Program
>
PR0231211
>
COMPLIANCE INFO 2004 - 2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/15/2019 3:05:27 PM
Creation date
5/15/2019 2:09:36 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2004 - 2008
RECORD_ID
PR0231211
PE
2371
FACILITY_ID
FA0002409
FACILITY_NAME
SAFEWAY FUEL CENTER #2707
STREET_NUMBER
6425
Direction
N
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
CURRENT_STATUS
01
SITE_LOCATION
6425 N PACIFIC AVE
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
268
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
RPR-30-2007 10:00 Service Station Systems 408 938 eee8 P.03 <br /> Monitori* System Equipmen "ertification <br /> For Use By All Jurisdictions Within The State of California <br /> Authority Cited., Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be, <br /> Mpared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided <br /> to the tank system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST system <br /> within 30 days of test date. <br /> A. General information <br /> Facility Name: Safeway 2707 Bldg.No-, <br /> Site Address: 6445 N. Pacific Ave.@ Central CL City: Stockton, CA Zip: 95207• <br /> Facility Contact Person: Aldo Contact Phone No.: (209)472.8600 <br /> Make/Model of Monitoring System: V/R TLS-35OR Date of Testing/Servicing: 419107 <br /> B. Inventory of Equipment Tested/Cerdffed <br /> Check the appropriate boxes to indicate specific equipment Inspeeted/serviecd: <br /> Tank ID: _ Tank 1D• <br /> ❑ In-Tank Gauging Probe. Model: p In-Tank Gauging Probe. Model: <br /> p Annular Space or Vault Sensor. Model: ❑ Annular Space or Vault Sensor. Model: <br /> O Piping Sump\Trench Sensor(s). Model: ❑ Piping Sump\Trench Sensor(s). Model: <br /> ❑ Fill Sump Sensor(s). Model: ❑ Fill Sump Sensor(s). Model: <br /> ❑ Mechanical Linc Leak Detector, Model: ❑ Mechanical Line Leak Detector. Model: <br /> a Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Modcl; <br /> ❑ Tank Overfill\High-Level Sensor. Model; ❑ Tank Overfill\High-Level Sensor. Model: <br /> ❑ Other(specify equipment type and model in Section E on Page 2). ❑ Other(specify equipment typo and model in Section F on Page 2). <br /> Tank IDL Tank IDL_ _ <br /> 0 In-Tank Gauging Probe. Model: ❑ In•Tank Gauging Probe. Model: <br /> ❑ Annular Space or Vault Sensor. Model: ❑ Annular Space or Vault Sensor. Model: <br /> ❑ Piping Sump\Trench Sensor(s). Model; ❑ Piping Sump\Trench Sensor(s). Model; <br /> ❑ Fill Sump Sensor(s). Model: ❑ Fill Sump Sensor(s). Model: <br /> p Mechanical Line Leak Detector. Model: 17 Mechanical Line Leak Detector, Model: <br /> O Electronic Line teak Defector. Model: p Electronic Line Leak Detector. Model: <br /> p Tank Overfill\High-Level Sensor. Model: ❑ Tank Overfill\High-Level Sensor. Model: <br /> ❑ Other(specify equipment type and model in Section E m Page 2). ❑ Olher(specify equipment type and model in Section E m Pago 2). <br /> Dispenser IDi 75 14 Dispenser ID• 16.16 <br /> M Dispenser Containment Sensor(s). Model: 1IR79u49-294 IN Dispenser Containment Sensor(s). Model: VR 794240.206 <br /> (% Sheat Valve(s). IN Shear Valve(s). <br /> (I Dispenser Contaimnent Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: Dispenser ID_ <br /> ❑ Dispenser Containment Sensor(s). Model: ❑ Dispenser Containment Sensor(s). Model: <br /> ❑ Shear Valve(s). ❑ Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). p Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID•_ Dispenser ID: <br /> ❑ Dispenses Containment Sensor(s). Model: ❑ Dispenser Containment Sensor(s). Model: <br /> p Shear Valve(s). ❑ Shear Valve(6). <br /> ❑ Dispenser Containment Float(s)and Chain(s), ❑ Dispenser Containment Float(s)and Chain(s). <br /> *If the facility contains more tanks or dispensers,copy this form.Include infonuation for every tank and dispenser at the facility <br /> C. Ceftifieation- t certify that the equipment identified in this document was inspected/serviced in accordance with the <br /> manufacturer's guidelines. Attached to this Cerfification is information(e.g.manufactures'eheeldists)necessary to verify that this <br /> information is correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such <br /> reports,f have also attached a copy of the; (check oa Mat apply): M System set-up IE Alarm history report <br /> Technician Name(print): Randy Wilkerson Signature: LbAL_. <br /> Mfg.CerL#.: A32404 ICC# 6258560-UT License,No.: 485184 <br /> Testing Company Name: Serv. Sta. SyS. _ Phone No,: _(40 971-2445 <br /> Site Addres3: 6445 N. Pacific Ave.@ Central Ct. Date of Testing/Servicing: 419107 <br />
The URL can be used to link to this page
Your browser does not support the video tag.