Laserfiche WebLink
«� <br /> J San Joaquin County DIRECOPY <br /> CTOR <br /> Donna Heran, REHS <br /> O.p4u!N' .0 Environmental Health Department ASSISTANT DIRECTOR <br /> .O <br /> 600 East Main Street Laurie Cotulla,REHS <br /> 4 Stockton, California 95202-3029 PROGRAM COORDINATORS <br /> J_ISa-_ Carl Borgman,REHS <br /> • Oq,..FOR ';P - Ov.or Mike Huggins,REHS,RD] <br /> Website: www.S/gov.org1ehd J9 8/ehd Margaret Lagorio,REHS <br /> Phone: (209)468-3420 Robert McClellon,REHS <br /> FOX: (209)464-0138 Jeff Carruesco,REHS,RDI <br /> Kasey Foley, REHS <br /> April 28,2008 <br /> Aldo Basurto Sent by:Fax and Certified Mail <br /> Safeway Fuel Center#2707 <br /> 6425 Pacific Ave <br /> Stockton,CA 95207 <br /> Fax:925-467-2591 <br /> SUBJECT: Underground Storage Tanks,Safeway Fuel Center,6425 Pacific Ave,Stockton,CA 95207 <br /> The San Joaquin County Environmental Health Department(EHD)has reviewed the secondary containment testing <br /> results report from testing performed on November 12,2007 for the above referenced site. <br /> The report indicates that the following Underground Storage Tank system components failed secondary containment <br /> testing: spill buckets,secondary containment product lines,under dispenser containment and turbine sumps. Most <br /> of these components have not been repaired and tested. <br /> Perform the following: <br /> r Current UST Facility form(former Form A) r Current UST Tank form(former Form B) <br /> I— Annual monitoring certification,leak detector <br /> r Annual Monitoring Certification and spill bucket test results <br /> r Monitoring and Response plans r Maintenance and monitoring logs <br /> r Certification of Financial Responsibility and Submit a permit application to repair or <br /> Letter from Chief Financial Officer replace failed equipment immediately <br /> r Designated Operator employee training r Statement of Designated Operator <br /> records <br /> r Certification of Return to Compliance(Signed r Statement of how each violation was or will <br /> and dated) be corrected <br /> The Underground Storage Tank secondary containment which is not tight at this facility,is a violation of <br /> Health and Safety Code§25291(a)(2). <br /> Note: All EHD staff time associated with failing to comply,including the issuance of this letter,is billed at the <br /> department rate,currently$98/hour. Failure to submit the requested information immediately may result in <br /> a reinspection or further legal action. <br /> Most forms may be accessed from our web site address,www.eeocities.com/unitiii. If you have any questions, <br /> please call Garrett Backus,REHS at(209)468-2986. <br /> Sincerely, <br /> Backus,REHS <br />