My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2008 - 2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
6425
>
2300 - Underground Storage Tank Program
>
PR0231211
>
COMPLIANCE INFO 2008 - 2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/4/2023 3:02:33 PM
Creation date
5/15/2019 2:15:18 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008 - 2011
RECORD_ID
PR0231211
PE
2371
FACILITY_ID
FA0002409
FACILITY_NAME
SAFEWAY FUEL CENTER #2707
STREET_NUMBER
6425
Direction
N
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
CURRENT_STATUS
01
SITE_LOCATION
6425 N PACIFIC AVE
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
437
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sigov.ora/ehd/unitiii.html <br /> CONTINUATION FORM Page: 3 of 4 <br /> OFFICIAL INP TI N REPORT Date: 06/20/11 <br /> Facility Address: 6425 Pacific Ave, Stockton Program: UST <br /> SUMMARY OF VIOLATIONS <br /> CLASS I CLASS 11 or MINOR-Notice to Com <br /> Routine and Monitoring System Certification UST Inspection <br /> 4. Financial responsibility documents have not been submitted to the EHD. Current financial <br /> responsibility documents are required to be submitted annually. Complete and submit a copy of the <br /> financial responsibility by July 20, 2011. <br /> 11. The 91/diesel tank annular sensor was raised approximately four inches off the lowest point of the <br /> tank bottom and was not located to detect a leak at the earliest opportunity. The tank riser was 174 <br /> inches and the sensor cord + sensor was 170 inches long. No liquid was detected in the tank annular <br /> space. Monitoring equipment shall be maintained to be able to detect a leak at the earliest possible <br /> opportunity. The testing technician lengthened the sensor cord and relocated this sensor to the lowest <br /> point of the 91/diesel tank annular space. <br /> 13. The vent sump liquid sensor failed to activate an audible and visual alarm when tested to ensure <br /> continuous monitoring of the tank system. All monitoring equipment shall be maintained to activate an <br /> audible and visual alarm or stop the flow of product at the dispenser when it detects a leak. The sensor <br /> (Veeder Root part 794380-208, S/N 865648) was replaced and retested during the inspection. Obtain a <br /> permit from the EHD for this work within one business day. If a permit is not obtained within one <br /> business day, a "Failure to Obtain a Permit" penalty will apply. <br /> 22. Diesel fuel was observed under dispensers 1 and 15 and was not recorded in facility records. Any <br /> release from the primary containment that does not escape the secondary containment and was cleaned <br /> up within eight hours of being detected shall be recorded with the following information: <br /> 1. Operator's name and phone number <br /> 2. List of types, quantities, and concentrations of hazardous substances released <br /> 3. Description of actions taken to control and clean the release <br /> 4. Method and location of disposal of the released substances <br /> 5. Description of actions taken to repair and prevent future releases <br /> 6. Description of method used to reactivate interstitial monitoring after repair or replacement of <br /> primary containment <br /> Immediately record this release with the information required, and maintain it on site with the facility's <br /> monitoring records. Submit a copy of the recordable release statement to the EHD by July 20, 2011. <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOMO DATES WILL BE BILLED AT THE CURRENT HOURLY RATE($122). <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> EHD 1 r RemiBy' Vie: _ s �� <br /> EHD2; 3 Rev08/10/10 �� CONTINUATION FORM <br />