Laserfiche WebLink
Monitoring System Certification-Page 2 of 3 <br /> Site Address: 6425 N. Pacific Ave. Date of Testing/Servicing: 6116/10 <br /> D. Results of Testing/Servicing <br /> Software Version Installed. 328.03 <br /> Complete the following checklist: <br /> B Yes 0 No* Is the audible alarm operational? <br /> Yes D No* Is the visual alarm operational? <br /> 0 Yes D No* Were all sensors visually inspected,functionally tested,and confirmed operational? <br /> to Yes D No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will <br /> not interfere with their proper operation? <br /> Yes 0 No* If alarms are relayed to a remote monitoring station, is all communications equipment(e.g.modem) <br /> 0 N/A operational? <br /> OI Yes 0 No* For pressurized piping systems,does the turbine automatically shut down if the piping secondary containment <br /> 0 N/A monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes:which sensors initiate <br /> positive shut-down? (Check all that apply) R Sump/Trench Sensors; B Dispenser Containment Sensors. <br /> Did you confirm positive shut-down due to leaks and sensor failure/disconnection? a Yes 0 No <br /> CI Yes 0 No* For tank systems that utilize the monitoring system as the primary tank overfill warning device(i.e.no <br /> 0 N/A mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br /> fill point(s)and operating properly? If so, at what percent of tank capacity does the alarm trigger? 89 % <br /> R Yes* 0 No Was any monitoring equipment replaced? If yes, identify specific sensors,probes,or other equipment replaced <br /> and list the manufacturer name and model for all replacement parts in Section E,below. <br /> 0 Yes* B No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) <br /> 0 Product;0 Water. If yes,describe causes in Section E,below. <br /> *Yes 0 No* Was monitorings stem set-up reviewed to ensure proper settings? Attach set-upreports, i applicable.) <br /> EX Yes 0 No* Is all monitoring equipment operational per manufacturer's specifications? <br /> * In Section E below,describe how and when these deficiencies were or will be corrected. <br /> E. Comments: 6/16110-Replaced Vent Sump Sensor-tested & passed. <br /> Replaced Syphon Jets on 87-1, 87-2& 91. <br /> Replaced Check Valve on 87-2. <br /> Need to return to repair& retest 87-2 & 91 PLLD's. <br /> 91 & Diesel are split tanks and share Annular. <br /> 6/21110 - Ran test on 87-2 and 91 & both PLLD's failed. <br /> Replaced syphon jet on 87-2, purged 600 gallons of fuel to get air out of line, retested & <br /> passed. <br /> Replaced preset check valve and syphon jet on 91, purged 600 gallons of fuel to get air out <br /> of line-all passed. <br />