Laserfiche WebLink
i <br /> Working To Restore Nature <br /> though the direction of flow cannot be specifically determined from the on-site wells, the <br /> direction can be safely assumed to be consistent with the nearby sites Momtonng well MW2 <br /> is appropriately located to monitor groundwater downgradient from the excavation and MW3 <br /> is adequate for upgradient observations <br /> The water samples collected from wells MW2 and MW3 on January 5, 1994 were analyzed for <br /> benzene, toluene, ethylbenzene and xylenes (BTEX) by EPA method 8020, total petroleum <br /> hydrocarbons as gasoline (TPHG) and total petroleum hydrocarbons as diesel (TPHD) by <br /> modified EPA method 8015 Dissolved petroleum hydrocarbons were not detected at or above <br /> method detection limits in monitoring wells MW2 or MW3 Analytical data is presented in <br /> Table 2 The laboratory data sheets, chain-of-custody, and monitoring data are included as <br /> Attachment 2 <br /> If you have any questions or comments please contact our Escalon office at 209/838-3507 <br /> Respectfully, <br /> RESNA Industries Inc <br />. Lois Frantz <br /> Project Geologist <br /> Greg P Stahl <br /> CA Registered Geologist No 5032 <br /> LF/gk <br /> Attachments <br /> PC Nick Kosta, BJJ Trucking <br /> Elizabeth Thayer, RWQCB - Central Valley Region <br /> OWO1691QUARTLY\1QR-1994 DRF <br />