Laserfiche WebLink
%W11 <br /> San Joaquin County <br /> Environmental Health Department DIRECTOR <br /> Donna Heran,REHS <br /> 185$ East Hazelton Avenue . <br /> Q: a s PROGRAM COORDINATORS <br /> N. s--={ Stockton, California 95205-6232 Robert McClellan,REHS <br /> Jeff Carruesco,REHS.RDI <br /> Website:wwsjgo!•or"g/ehd Kasey Foley,RENS <br /> w. <br /> Linda Turkatte,RENS <br /> Phone: (209)468-3420 <br /> Fax: (209)464-0138 <br /> January 31, 2013 <br /> Mrs. Winifred Alexander Mr. Sarbjit Singh Sarao <br /> Mary Gardella Trust 1305 South Wilson Way <br /> 525 2nd Street Stockton, California 95205' <br /> Santa Cruz, California 95060 <br /> Estate of Mr. Joseph Gardella <br /> Mr. Dennis Caspe, Esquire <br /> 2035 North Pacific Avenue <br /> Santa Cruz, California 95060 <br /> Subject: Former Stefano's Gasoline Station <br /> 1419 East Charter Way <br /> Stockton, California 95205 <br /> The San Joaquin County Environmental Health Department (EHD) has received and reviewed <br /> Well Destruction Work Plan (work plan), dated 18 January 2013, submitted by your consulting <br /> firm, Advanced GeoEnvironmental, Inc. (AGE), on your behalf for the above-referenced site. <br /> The EHD had directed the submittal of a well destruction work plan by letter dated 31 October <br /> 2012. <br /> In the work plan, AGE proposes to destroy monitoring wells MW-1, MW-3, MW-4, MW-5, MW-6, <br /> MW-7, soil vapor extraction wells SVE-4 and SVE-5, and ozone sparge wells OZ-2 and OZ-3 by <br /> pressure grouting; and MW-2, MW-8, SVE-1, SVE-2, SVE-3, OZA and OZ-4 by removing the <br /> well components by over-drilling the wells. Although it is unclear whether AGE proposes to <br /> pressure grout or over-drill MW-9, the EHD approves this well to be pressure grouted since <br /> contaminants of concern have not been detected in any soil or groundwater samples collected <br /> from MW-9. <br /> The San Joaquin County Well Standards require over-drilling and removing well contents as the <br /> method of destruction if the well is in an area of known or suspected contamination. The EHD <br /> has reviewed the site soil data to determine if the wells proposed for destruction by pressure <br /> grouting qualify for that destruction method. The EHD determined that the following wells <br /> qualify for destruction by pressure grouting: MW-1, MW-4, MW-5, MW-6, MW-7, MW-9, SVE-4, <br /> SVE-5, and OZ-2. <br /> The remaining wells: MW-2, MW-3, MW-8, SVE-1, SVC-2, SVE-3, OZA, OZ-3 and OZ-4, have <br /> either impacted groundwater or are located in an area of known or suspected contamination. <br /> These wells must be destroyed by removal of the well contents prior to grouting from the bottom <br /> upward using a tremie pipe. <br />