Laserfiche WebLink
. Quarterly Report - Third Quarter 2004 <br /> Former STEFANOS GAS STATION <br />' 1419 East Charter Way, Stockton, California <br />' 1.0. INTRODUCTION ` <br /> At the ,request of Mrs Winfred Alexander, executor of Mary Gardella Trust, Advanced <br />' GeoEnvfronmentaI, Inc (AGE) has prepared this quarterly report for the property located at 1419 <br /> East Charter Way, Stockton, California (site) The objective of the work was to monitor dissolved <br /> petroleum hydrocarbon concentrations in ground water and to characterize ground water elevation, <br />' flow direction, and hydraulic gradient on-site The site and the surrounding area are illustrated on <br /> Figure 1 On-site structures and monitoring well locations are illustrated on Figure 2 <br /> , <br /> n 2.0 PROCEDURES, <br />' Field procedures were performed in accordance with Central Valley Regional Water Quality Control <br /> Board(CVRWQCB)and San Joaquin County Environmental Health Department(EHD)guidelines <br />' for investigating underground storage tank(UST)sites and sampling ground water monitoring wells <br />' 2 1 WELL MONITORING AND EVACUATION <br /> On 31 August 2004, ground water monitoring and sampling were performed on monitoring wells <br /> MW-1 through MW-7 Prior to sampling, the depth to ground water was measured from the top of <br /> each well casing to the nearest 0 01-foot utilizing a Solmst water level meter The ground water <br /> elevation in each well was calculated by subtracting the measured depth to ground water from the <br />' surveyed casing elevation (Table 1) <br /> After water levels were measured, each monitoring well was purged of standing water utilizing a <br />' new,disposable plastic bailer Approximatelyl. 75 to 3 gallons of water(a minimum of three casing- <br /> water volumes)were removed from each well Groundwater temperature,pH,and conductivity were <br /> measured at regular intervals during purging using an Oakton water analyzer Field sheets and data <br />' are included in Appendix A Purged water was stored on-site in appropriately labeled, 55-gallon <br /> s Department of Transportation (DOT)-approved drums pending proper disposal µ <br /> 1 <br /> 22 COLLECTION OF GROUND WATER SAMPLES <br /> Water samples we're collected from the purged wells using new, disposable plastic bailers after <br /> allowing the wells to achieve a minimum 80%recovery of the pre-purge water volume Each water <br /> I sample was transferred into four 40-milliliter(ml)volatile organic analysis(VOA)vials containing <br /> 0 5 ml 18%hydrochloric acid solution as a sample preservative After collection, the samples were <br /> Advanced GeoEnVLronmental, Inc <br />